Autoped/ M10 APPENDIX rev 0 (09221 DRAFT)
A-30
Error No
Description
Cause
Elimination
Checking time
Reaction
E22 01
NOT test
NOT input on 24v
Check the jumper NOT. Check the
cabling of the NOT
Permanent
H
02
Malfunction
Restart the control unit SW update
necessary
After power up
E30 01
30v error
30v too low
Main’s failure, overload motor.
Check 115vac line. Replace
hardware
Permanent
A
02
30v too high
03
Error upon switching on
After power up
E31 01
24v general
Error upon switching on
Overload, short circuit of the 24v
inputs (without electric lock, safety
sensors)
After power up
A (restart
after 10
seconds)
02
Over-resp, under-voltage
permanent
E32 01
24v safety
Over-resp, under voltage
Overload, short circuit safety
sensors
E33 01
24v E-lock
Error: over-resp under
voltage
Overload, short circuit electric lock
02
Premonition: over-resp
under voltage
w
E34 01
24v CAN
Over resp under voltage
Overload, short circuit external
power supply CAN
E60 00
Relay PCB 0
Optional PCB has been
removed, its address
changed or became
defective
Check if the option is provided.
If defective: replace or remove
from configuration.
Permanent
W
10
Relay PCB 1
W
20
Radio PCB
W
30
Fire
Protection
A
E50 01-
99
System error
Unexpected hardware or
software event
Switch the drive unit Off/On.
Carry out a Factory Reset, Carry
out a software update, inform the
manufacturer
permanent
W or H or F
E51
E52
E70 XX CAN bus
setting
CAN address XX existing
twice
Correctly define the role of the
closing sequence or the interlock
function
Permanent
W
E71 01
CAN
connection
No CAN connection
Plug in, check, or replace the CAN
cable
Check if all the CAN participants
are switched on
Permanent
W
Summary of Contents for AUTOPED 10
Page 1: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 1 AUTOPED TM MODEL 10 OPERATOR APPENDIX 2021...
Page 17: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 17 SECTION IV MENUS AND PROGRAMMING...
Page 26: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 26 SECTION V TROUBLE SHOOTING AND ERROR CHARTS...
Page 39: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 39 Fig VI 5 Secured Activation Devices...
Page 40: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 40 Fig VI 6 Wiring for Double Door Gate System...
Page 41: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 41 SECTION VII SERVICE PARTS...
Page 42: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 42 VII 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...