Autoped/ M10 APPENDIX rev 0 (09221 DRAFT)
A-22
Device
Unit type
Default
Value
Description
Device
Rod
Full and low
STD-PH
STD-PH
Outswing
arm and
Arm-Shoe
Push function
Motor cable connector: X=orange
SLI-PL
Inswing arm
with track
and roller
Pull function
Motor cable connector: Y=Green
SLI-PH
Outswing
with inswing
track and
roller
Push function
Motor cable connector: X=orange
Rod
Low energy
STD-PH
If panic breakout latch is installed and the motor is plugged in backwards or the
wrong arms are chosen during programming, there is a possibility the Door/Gate
panel can burst open unexpectedly towards the installer once TEACH mode is
initiated.
Teach must be activated after this setting has been changed.
Inverse Low energy
Off
Off-
On
In the event of a power failure/error, the Door/Gate panel is opened by spring
power from any position (unless it has been locked). The position of the motor
connector is reversed regarding the standard drive unit.
Teach must be activated after this setting has been changed.
dAxis
Low energy
7in
2-
25in
Distance between center line of the door hinges and the mounting surface of the
operating assembly. dAxis is an approximate value. Depending on the
installation situation, dAxis may have to be estimated.
Teach must be activated after this setting has been changed.
IV.7 CONFIGURATION MENU OPTIONS AND DEFINITIONS
Device
Unit type
Default
Description
APuGO
Off
Off, 2°-10°
Triggering angle for Push and Go (angle Push and Go)
ASES
95°
45°-95°
Lock out angle:
Angle at which the swing side Door/Gate panel mounted sensor is ignored just
before open/
If Ao is changed, ASES is automatically set to Ao.
ASER
0°
0°-60°
Lock out angle: angle at which push side of the Door/Gate panel sensor is
ignored just before closing.
SESClo
Inactive
Active
Sensor mounted on swing side of Door/Gate is activated or inactivated during
closing cycle
Inactive
Summary of Contents for AUTOPED 10
Page 1: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 1 AUTOPED TM MODEL 10 OPERATOR APPENDIX 2021...
Page 17: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 17 SECTION IV MENUS AND PROGRAMMING...
Page 26: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 26 SECTION V TROUBLE SHOOTING AND ERROR CHARTS...
Page 39: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 39 Fig VI 5 Secured Activation Devices...
Page 40: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 40 Fig VI 6 Wiring for Double Door Gate System...
Page 41: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 41 SECTION VII SERVICE PARTS...
Page 42: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 42 VII 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...