Autoped/ M10 APPENDIX rev 0 (09221 DRAFT)
A-23
Device
Unit type
Default
Description
EMY-IN
CL-SPR
Configuration of the emergency terminal (break contact switch)
CL-SPR
Spring close (standard application)
STOP
Stops Door/Gate panel closing/opening
OPEN
Opens the Door/Gate panel
CL-MOT
Motor close (inverse application)
OExSTp Off
Off
N/A
Used to setone of the activation “values” to “sequential”
mode.
Sequential mode is used to hold the door open until a
second activation is received.
One activation opens the Door/Gate panel, and a
second activation is required to close the Door/Gate
panel.
OEI
Opening devise
inside
OEO
Opening devise
outside
KEY
Key opening
devise
RADIO
N/A
UNLOCK PERMAN
IMPULS
When the Door/Gate panel is first opened: momentarily unlocks the electric lock
PERMAN
When the Door/Gate panel is first opened: Permanently unlocks the electric
lock.
EL-FB
Off
Off
Electric lock status feedback
N.O.
Open if unlocked (-); closed if locked (+)
N.C.
Open if locked (+); closed if unlocked (-)
Lock AU UNLOCK
UNLOCK/LOCK
Sets the condition of the lock when in automatic mode.
Only visible when Unlock is set to PERMAN.
LockEX
LOCK
UNLOCK/LOCK
Sets the condition of the lock when in EXIT mode.
Only visible when Unlock is set to PERMAN
LockMA
UNLOCK
UNLOCK/LOCK
Sets the condition of the lock when in MANUAL mode.
Only visible when Unlock is set to PERMAN
LcdDir
0
0-1
Orientation of the display (LCD direction)
MovCon
OFF
OFF/ON
Endurance test Open/Close (moving continuous)
Pre Sen N.C.
Off/N.C./N.O.
Swing side presence sensor output logic
OExMAN ON
OFF/ON
On enables activation to reopen the door during the closing cycle of a
manual opening.
OExMAN only if APuGo is turned OFF
Summary of Contents for AUTOPED 10
Page 1: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 1 AUTOPED TM MODEL 10 OPERATOR APPENDIX 2021...
Page 17: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 17 SECTION IV MENUS AND PROGRAMMING...
Page 26: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 26 SECTION V TROUBLE SHOOTING AND ERROR CHARTS...
Page 39: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 39 Fig VI 5 Secured Activation Devices...
Page 40: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 40 Fig VI 6 Wiring for Double Door Gate System...
Page 41: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 41 SECTION VII SERVICE PARTS...
Page 42: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 42 VII 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...