Autoped/ M10 APPENDIX rev 0 (09221 DRAFT)
A-20
IV.6 CHART FOR OPTIONS IN THE PARAMETER MENU: SETTINGS FOR DOOR/GATE MOVEMENT
Device
Unit type
Default
Value
Description
Region Both
Eu
Eu or us
EU- Europe; US- united states
Software version determined by UL standards. Must be changed to
US
Vo
Low energy
9
0-9
Vc
Low energy
9
0-9
TOEx
Low energy
5s
3-60s
ANSI 156.19 for low energy: TOEx must be no less than 5 seconds
TKey
Low energy
5s
3-180s
TKey sets the hold open time resulting from an activation signal
from a device (referred to as KEY) on terminals 2+3
With TOEx and TKey, you can set a different hold open time for
different activation devices by using different terminals
TPuGo Low energy
3s
3-180s
Determines how long the Door/Gate stays open
TDelay Low energy
.2s
0.0-4.0s
Tdelay sets the amount of time the door hesitates to allow the lock to
release before opening.
FDelay Low energy
Off
Off-7.0A
Fdelay is a temporary “hold closed” force applied to the door to keep it
closed while the electric lock is being released. This parameter sets
the amount of force that is applied. FDelay is only active if TDelay
setting is greater than 0.
TLock
Low energy
0.5s
0.0-4.0s
Sets amount of time Door/Gate panel will press against lock to engage
it.
Flock
Low energy
2.0A
Off-7.0A
Sets amount of force that is applied to the Door/Gate panel to engage
the lock at the closed position. It is only active if TLock setting is
greater than 0.
FSlam
Low energy
Off
Off-10
Accelerating function (Force Slam). For example: when a Door/Gate
panel needs to be forced shut due to a latch or heavy seals.
Summary of Contents for AUTOPED 10
Page 1: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 1 AUTOPED TM MODEL 10 OPERATOR APPENDIX 2021...
Page 17: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 17 SECTION IV MENUS AND PROGRAMMING...
Page 26: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 26 SECTION V TROUBLE SHOOTING AND ERROR CHARTS...
Page 39: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 39 Fig VI 5 Secured Activation Devices...
Page 40: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 40 Fig VI 6 Wiring for Double Door Gate System...
Page 41: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 41 SECTION VII SERVICE PARTS...
Page 42: ...Autoped M10 APPENDIX rev 0 09221 DRAFT A 42 VII 1 SERVICE PARTS COMPONENTS VISUAL GUIDE...