54
Operating Manual Ultralight 402
Deutsch
English
Fault codes
Display
Cause
What to do
E02
Stator over-temperature
(engine overheating)
Motor can be used again after a short wait
(about 10 minutes). Contact Torqeedo Service.
E03, E04
Motor tilted during
operation
Motor can be used again after tilting it down
and pressing on/off.
E05
Motor/propeller blocked
Loosen blockage and turn propeller one
revolution by hand.
E06
Voltage in the motor too
low
Low battery charging status. Motor can be
used again slowly from the stop position.
E07
Motor overcurrent
Continue at low output. Contact Torqeedo
Service.
E08
Circuit board overheating Motor can be used again after a short wait
about 10 minutes). Contact Torqeedo Service.
E21
Remote throttle
calibration defective
• Re-calibrate:
Press “cal” button for 10 seconds.
• The display shows “cal up”:
Press remote throttle control forward to
full gas then press the “cal” button.
• The display shows “cal stp”:
Return remote throttle control to central
position then press the “cal” button.
• The display shows “cal dn”:
Press remote throttle control reverse to full
gas then press the “cal” button.
E22
Magnetic sensor
defective
Re-calibrate (refer to E21).
E23
Value range false
Re-calibrate (refer to E21).
E30
Motor communication
error
Check the motor cable’s plug-in connection.
Check the motor cable for damage.
E32
Remote throttle control
communication error
Check the remote throttle control cable’s
plug-in connection.
E33
General communication
error
Check the plug-in connections and cables.
Switch the motor off and on again.
E41, E42
Incorrect charging
voltage
Check whether the power supply unit used
has an output voltage between 10 V and 20 V.
If necessary contact Torqeedo Service.