72
Deutsch
English
4.9 Using solar panels and generators
Solar panels and generators can only be used if a battery bank is connected between them
and the motor. The battery bank will even out voltage peaks of the solar panels and genera-
tors (acts as a buffer) which will avoid damages due to overvoltage.
Use a Torqeedo charger to charge Power 26-104 from generator. Do not connect generators
directly with Power 26-104. To connect the Power 26-104 with a solar charger a specificated
solar charge controller is available. Do not connect solar panels directly to Power 26-104.
5. Operation
5.1 Driving operation
To start the motor, switch it on, apply magnetic key and turn the tiller
handle from the stop-position into the desired direction.
1.
2.
3.
12 V battery
12 V battery
12 V battery
12 V battery
Bridging cable
Bridging cable
12 V devices
24 V devices
Bridging cable