g026143
Figure 57
1.
Reserve tank-cap
2.
Reserve tank
5.
Disconnect the lower radiator hose and allow
the coolant to flow into a drain pan.
Note:
When the coolant stops flowing, connect
the lower radiator hose.
6.
Slowly fill the radiator with a 50/50 mixture of
water and permanent ethylene-glycol antifreeze
7.
Top off the radiator and install the cap (
8.
Slowly fill the coolant-reserve tank until level
reaches the bottom of the filler neck (
).
9.
Install the reserve-tank cap (
).
10.
Start the engine and operate it until it is warm.
11.
Shut off the engine, check the coolant level, and
replenish the coolant, if necessary.
Brake Maintenance
Checking the Brake-Fluid
Level
Service Interval:
Before each use or daily—Check
the brake-fluid level. Check the
brake-fluid level before you first start
the engine.
Every 1,000 hours/Every 2 years (whichever
comes first)—Change the brake fluid.
Brake-fluid type:
DOT 3
1.
Park the machine on a level surface.
2.
Engage the parking brake.
3.
Shut off the engine and remove the key.
4.
Raise the hood to access to the master brake
cylinder and reservoir (
).
g009817
Figure 58
1.
Brake-fluid reservoir
5.
Ensure that the fluid level is up to the Full line on
the reservoir (