Fault Code (Lamp Flashes)
Fault Description
1 -- 1
High engine temp warning occurred (PTO was shutdown by ECM)
1 -- 2
High engine temp shutdown occurred (engine was shutdown by ECM)
1 -- 3
Low engine oil pressure occurred
1 -- 4
Engine alternator fault occurred
1 -- 5
Charging system voltage was incorrect (check charging system)
1 -- 6
Internal ECM fault
2 -- 1
Check ECM output fuse 1
2 -- 2
Check ECM output fuse 2
2 -- 3
Check ECM output fuse 3
2 -- 4
No power to all ECM output fuses (check main power relay)
2 -- 5
Leak in hydraulic system detected by optional leak detector (reels shutdown
and leak detector alarm sounds)
3 -- 1
Glow plug relay current was too high (check glow plug circuit)
3 -- 2
Start relay current was too high (check starting circuit)
3 -- 3
Fuel stop solenoid and fuel pump current were too high
3 -- 5
MSV2 current was too high (check front mow electrical circuit)
4 -- 1
SV1 current was too high (check cutting unit lift electrical circuit)
4 -- 2
SV3 current was too high (check cutting unit lift electrical circuit)
4 -- 3
SV2 current was too high (check cutting unit lift electrical circuit)
4 -- 4
SVRV current was too high (check cutting unit lift electrical circuit)
4 -- 5
MSV1 current was too high (check rear mow electrical circuit)
5 -- 1
Signal from optional leak detector was lost
5 -- 4
Internal ECM fault
Clearing Fault Codes
After fault codes have been retrieved, clearing of those
faults from ECM memory can be completed using the
following switch sequence:
1. Place machine switches in fault retrieval (see
above). The diagnostic light should be displaying the
fault codes.
2. Operator seat should remain UNOCCUPIED.
3. Move both mow/backlap levers to BACKLAP.
4. Move joystick to the RAISE position.
5. Monitor the diagnostic light for continuous flash-
ing indicating that all faults have been cleared from
ECM memory.
If more than 3 faults exist in the ECM memory, additional
faults can be retrieved using the above procedures. If a
fault is not retrieved from ECM memory within 40 hours
of machine operating time, the fault will be automatically
cleared.
Electrical System
Summary of Contents for Reelmaster 5210
Page 2: ...Reelmaster 5010 Series This page is intentionally blank ...
Page 4: ...Reelmaster 5010 Series This page is intentionally blank ...
Page 32: ...Reelmaster 5010 Series Page 3 18 Kubota Diesel Engine This page is intentionally blank ...
Page 148: ...Reelmaster 5010 Series Hydraulic System Rev C Page 4 116 This page is intentionally blank ...
Page 204: ...Reelmaster 5010 Series Page 5 56 Electrical System This page is intentionally blank ...
Page 207: ...Reelmaster 5010 Series Page 6 3 Chassis Rev C This page is intentionally blank Chassis ...
Page 215: ...Reelmaster 5010 Series Page 6 11 Chassis Rev C This page is intentionally blank Chassis ...
Page 230: ...Reelmaster 5010 Series Page 6 26 Chassis Rev C This page is intentionally blank ...
Page 270: ...Reelmaster 5010 Series Cutting Units Rev C Page 7 40 This page is intentionally blank ...
Page 279: ...Reelmaster 5010 Series Groomer Page 8 9 This page is intentionally blank Groomer ...
Page 288: ...Reelmaster 5010 Series Foldout Drawings Page 9 2 This page is intentionally blank ...
Page 297: ...Rev B Page 9 11 This page is intentionally blank ...
Page 298: ...Rev B Page 9 12 Reelmaster 5010 Series Main Wire Harness Drawing ...
Page 300: ...Rev B Page 9 14 Reelmaster 5010 Series Seat Wire Harness Drawing ...
Page 302: ...Rev B Page 9 16 Reelmaster 5010 Series Engine Wire Harness Drawing ...