Reelmaster 5010 Series
Page 5 -- 38
Electrical System
Diode Assembly
A diode assembly (Fig. 45) is used in the Reelmaster en-
gine wire harness (see wire harness drawings in Chap-
ter 9 -- Electrical Diagrams). The diode is used for circuit
protection from voltage spikes that occur when the start-
er solenoid is de--energized.
Testing
Locate diode assembly and remove cable tie that se-
cures diode to wire harness. Unplug the diode from the
wire harness for testing. The diode (Fig. 46) can be
tested using a digital multimeter (diode test or ohms set-
ting) and the table
below
. After testing is complete,
make sure that diode is fully installed into harness con-
nector and secured to harness with cable tie.
Multimeter
Red Lead (+)
on Terminal
Multimeter
Black Lead (--)
on Terminal
Continuity
Female
Male
YES
Male
Female
NO
1. Engine wire harness
2. Diode assembly
Figure 45
2
1
Figure 46
1. Diode
2. Male terminal
3. Female terminal
1
2
3
Fusible Link Harness
The Reelmaster uses three (3) fusible links for circuit
protection. These fusible links are located in a harness
that connects the starter B+ terminal to the main wire
harness (Fig. 47). If any of these links should fail, current
to the protected circuit will cease. Refer to wire harness
drawings in Chapter 9 -- Electrical Diagrams for addi-
tional fusible link information.
Testing
Make sure that ignition switch is OFF and disconnect
negative battery cable from battery terminal. Then dis-
connect positive cable from battery (see Battery Service
in the Service and Repairs section of this chapter). Lo-
cate and unplug fusible link connector P1 from machine
wire harness. Use a multimeter to make sure that conti-
nuity exists between each terminal pin in connector P1
and connector J1 at the starter (Fig. 48). If any of the fus-
ible links are open, replace the fusible link harness.
After testing is complete, make sure that fusible link har-
ness connectors are securely attached to starter and
machine wire harness. Connect positive battery cable to
battery terminal first and then connect negative cable to
battery.
1. Starter motor
2. Fusible link harness
Figure 47
2
1
Figure 48
FUSIBLE LINK
FUSIBLE LINK
FUSIBLE LINK
Summary of Contents for Reelmaster 5210
Page 2: ...Reelmaster 5010 Series This page is intentionally blank ...
Page 4: ...Reelmaster 5010 Series This page is intentionally blank ...
Page 32: ...Reelmaster 5010 Series Page 3 18 Kubota Diesel Engine This page is intentionally blank ...
Page 148: ...Reelmaster 5010 Series Hydraulic System Rev C Page 4 116 This page is intentionally blank ...
Page 204: ...Reelmaster 5010 Series Page 5 56 Electrical System This page is intentionally blank ...
Page 207: ...Reelmaster 5010 Series Page 6 3 Chassis Rev C This page is intentionally blank Chassis ...
Page 215: ...Reelmaster 5010 Series Page 6 11 Chassis Rev C This page is intentionally blank Chassis ...
Page 230: ...Reelmaster 5010 Series Page 6 26 Chassis Rev C This page is intentionally blank ...
Page 270: ...Reelmaster 5010 Series Cutting Units Rev C Page 7 40 This page is intentionally blank ...
Page 279: ...Reelmaster 5010 Series Groomer Page 8 9 This page is intentionally blank Groomer ...
Page 288: ...Reelmaster 5010 Series Foldout Drawings Page 9 2 This page is intentionally blank ...
Page 297: ...Rev B Page 9 11 This page is intentionally blank ...
Page 298: ...Rev B Page 9 12 Reelmaster 5010 Series Main Wire Harness Drawing ...
Page 300: ...Rev B Page 9 14 Reelmaster 5010 Series Seat Wire Harness Drawing ...
Page 302: ...Rev B Page 9 16 Reelmaster 5010 Series Engine Wire Harness Drawing ...