1 2
3 4
Maximum communication
wire length between the
controller and the farthest
module is 15,000' (4,500 m).
White
White
Black
Black
White
White
Black
Black
The maximum communication wire length
between the module and the solenoid is
410' (125m).
Recommended Cable for Module-
to-Solenoid: 14 AWG, Solid Copper,
2-Conductor, Direct Burial cable.
To easily identify stations for
troubleshooting, install wires with the same
color code as the station wires.
Each station can activate
up to two DC Latching
Solenoids.
Out to additional
modules
Station Wires
The Lynx SmartHub output board can accommodate two
cable paths with up to 250 stations each .
1-Station
Module
Recommended Cable for Controller-to-Decoder is 14 AWG,
Solid Copper, Jacketed 2-Conductor, Direct Burial cable.
Figure 8
Daughterboard
LSM with hard-wired solenoid
Black and white
control wires to black
and white control
wires from controller.
INFINITY w/ LSM
FLEX800 w/ LSM
P220 valve w/ LSM
11