Groundsmaster 4000--D
Page 5 -- 36
Electrical System
A. Measure the specific gravity of each cell with a
hydrometer. Draw electrolyte in and out of the
hydrometer barrel prior to taking a reading to warm--
up the hydrometer. At the same time take the tem-
perature of the cell.
B. Temperature correct each cell reading. For each
10
o
F (5.5
o
C) above 80
o
F (26.7
o
C) add 0.004 to the
specific gravity reading. For each 10
o
F (5.5
o
C) be-
low 80
o
F (26.7
o
C) subtract 0.004 from the specific
gravity reading.
Example: Cell Temperature
100
o
F
Cell Gravity
1.245
100
o
F minus 80
o
F equals 20
o
F
(37.7
o
C minus 26.7
o
C equals 11.0
o
C)
20
o
F multiply by 0.004/10
o
F equals 0.008
(11
o
C multiply by 0.004/5.5
o
C equals 0.008)
ADD (conversion above)
0.008
Correction to 80
o
F
(26.7
o
C)
1.253
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cell specific gravity is less than 1.225, charge the bat-
tery. Charge at the recommended rate and time giv-
en in
Charging
or until all cells specific gravity is
1.225 or greater with the difference in specific gravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
3. Perform a high--discharge test with an adjustable
load tester.
This is one of the most reliable means of testing a battery
as it simulates the cold--cranking test. A commercial bat-
tery load tester is
required
to perform this test.
CAUTION
Follow the manufacturer’s instructions when us-
ing a battery load tester.
A. Check the voltage across the battery terminals
prior to testing the battery. If the voltage is less than
12.4 VDC, charge the battery before performing a
load test.
B. If the battery has been charged, apply a 150 amp
load for 15 seconds to remove the surface charge.
Use a battery load tester following the manufactur-
er’s instructions.
C. Make sure battery terminals are free of corrosion.
D. Measure the temperature of the center cell.
E. Connect a battery load tester to the battery termi-
nals
following the manufacturer’s instructions
.
Connect a digital multimeter to the battery terminals.
F. Apply a test load of 325 amps (one half the crank-
ing performance rating of the battery) for 15 se-
conds.
G. Take a battery voltage reading at 15 seconds,
then remove the load.
H. Using the table below, determine the minimum
voltage for the cell temperature reading:
Minimum
Voltage
Battery Electrolyte
Temperature
9.6
70
o
F (and up)
21.1
o
C (and up)
9.5
60
o
F
15.6
o
C
9.4
50
o
F
10.0
o
C
9.3
40
o
F
4.4
o
C
9.1
30
o
F
--1.1
o
C
8.9
20
o
F
--6.7
o
C
8.7
10
o
F
--12.2
o
C
8.5
0
o
F
--17.8
o
C
I. If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
Summary of Contents for Groundsmaster 4000-D
Page 2: ...Groundsmaster 4000 D This page is intentionally blank ...
Page 4: ...Groundsmaster 4000 D This page is intentionally blank ...
Page 10: ...Groundsmaster 4000 D Page 1 6 Safety This page is intentionally blank ...
Page 34: ...Groundsmaster 4000 D Page 3 18 Kubota Diesel Engine This page is intentionally blank ...
Page 212: ...Groundsmaster 4000 D Page 5 38 Electrical System This page is intentionally blank ...
Page 253: ...Groundsmaster 4000 D Page 7 11 Chassis This page is intentionally blank Chassis ...
Page 264: ...Groundsmaster 4000 D Page 7 22 Chassis This page is intentionally blank ...
Page 269: ...Groundsmaster 4000 D Cutting Decks Page 8 5 This page is intentionally blank Cutting Decks ...
Page 282: ...Groundsmaster 4000 D Foldout Drawings Page 9 2 This page is intentionally blank ...
Page 292: ...Page 9 12 Groundsmaster 4000 D Engine Wire Harness STARTER STARTER STARTER ...
Page 294: ...Page 9 14 Groundsmaster 4000 D Front Wire Harness FLOW DIVIDER SOLENOID ...