Groundsmaster 4000--D
Page 5 -- 21
Electrical System
TEC--5002 Controller
Groundsmaster 4000--D machines use a Toro Electron-
ic Controller (TEC) to control the operation of the hy-
draulic cooling fan. The controller is attached to the
operator platform under the console housing cover (Fig.
32).
Logic power is provided to the controller as long as the
battery cables are connected to the battery. A 2 amp
fuse in a fuse holder near the battery provides circuit
protection for this logic power to the controller.
The TEC--5002 controller monitors the states of the fol-
lowing components as inputs: ignition switch, hydraulic
temperature sender, engine coolant temperature send-
er and cooling fan switch.
The TEC--5002 controller controls electrical output to
the engine cooling fan hydraulic valve solenoid coils
(speed and direction). Circuit protection for TEC--5002
outputs is provided by fuse F9 (7.5 amp).
Because of the solid state circuitry built into the TEC,
there is no method to test the controller directly. The con-
troller may be damaged if an attempt is made to test it
with an electrical test device (e.g. digital multimeter or
test light).
1. Fuses
2. TEC location
Figure 32
1
2
Electrical System
Summary of Contents for Groundsmaster 4000-D
Page 2: ...Groundsmaster 4000 D This page is intentionally blank ...
Page 4: ...Groundsmaster 4000 D This page is intentionally blank ...
Page 10: ...Groundsmaster 4000 D Page 1 6 Safety This page is intentionally blank ...
Page 34: ...Groundsmaster 4000 D Page 3 18 Kubota Diesel Engine This page is intentionally blank ...
Page 212: ...Groundsmaster 4000 D Page 5 38 Electrical System This page is intentionally blank ...
Page 253: ...Groundsmaster 4000 D Page 7 11 Chassis This page is intentionally blank Chassis ...
Page 264: ...Groundsmaster 4000 D Page 7 22 Chassis This page is intentionally blank ...
Page 269: ...Groundsmaster 4000 D Cutting Decks Page 8 5 This page is intentionally blank Cutting Decks ...
Page 282: ...Groundsmaster 4000 D Foldout Drawings Page 9 2 This page is intentionally blank ...
Page 292: ...Page 9 12 Groundsmaster 4000 D Engine Wire Harness STARTER STARTER STARTER ...
Page 294: ...Page 9 14 Groundsmaster 4000 D Front Wire Harness FLOW DIVIDER SOLENOID ...