10. Connect the middle lead with the spade connector to the
open lead on the fuse box under the driver’s seat
(Fig. 22 and 25).
m–6396
1
2
3
4
Figure 25
1.
Middle lead with a spade
connector
2.
Open position on the fuse
block
3.
Middle lead with an
eye-ring connector
4.
Ground terminal block
11. If necessary, install a 10 amp fuse in the position where
you connected the wire.
12. Connect the middle lead with the eye ring connector to
a ground stud on the ground terminal block (Fig. 25).
13. Connect the connector with mostly green and yellow
wires to the spray selection switch (toggle style switch)
(Fig. 26).
m–6397
2
1
4
3
Figure 26
1.
Spray selection switch
2.
Connector with mostly
green and yellow wires
3.
Rate control switch
4.
Connector with
multi-colored wires
14. Connect the connector with the multi-colored wires to
the rate control switch (momentary switch) (Fig. 26).
15. Install the switch wire cover over the switches and
around the wires (Fig. 27) and secure it with
4 flange-head bolts (1/4 x 3/4 inch) and 4 flange nuts
(1/4 inch).
m–6391
1
2
Figure 27
1.
Switch wire cover
2.
Wire harness
16. Connect the small red tube to the silver fitting you
installed in step 4 and the other end to the fitting on the
bottom of the pressure gauge.
17. Install the control box cover to the control box
mounting bracket (Fig. 28), using 5 flange-head bolts
(1/4 x 3/4 inch).
m–6390
2
2
1
3
2
Figure 28
1.
Control box cover
2.
Flange-head bolt,
1/4 x 3/4 inch
3.
Knob
18. Install the knob onto the valve control lever (Fig. 28).