![Toro 34215 Operator'S Manual Download Page 45](http://html1.mh-extra.com/html/toro/34215/34215_operators-manual_1133878045.webp)
Cleaning the Strainer
Service Interval:
After each use
Important:
If you used wettable-powder
chemicals, clean the strainer after each time that
you rinse the sprayer tank.
1.
Empty the sprayer tank; refer to
Sprayer Tank (page 39)
.
2.
Rotate the handle of the pump-shutoff valve 90°
counterclockwise to the
CLOSE
position (
g249175
Figure 51
1.
Strainer
2.
Pump-shutoff valve
3.
Align a drain pan under the strainer (
4.
Rotate the strainer bowl counterclockwise and
remove the bowl and screen from the body of
the strainer (
Note:
Remove the strainer bowl by hand.
Note:
Replace the gasket or screen or both if
these parts are worn or damaged
g027402
Figure 52
1.
Strainer body
3.
Screen
2.
Gasket
4.
Strainer bowl
5.
Allow any residual chemical solution to drain
from the strainer body.
Note:
Dispose of the waste solution according
to local codes and the chemical manufacturer's
instructions.
6.
Use a soft-bristle brush and clean water to clean
the screen and bowl
7.
Install the screen into the strainer body (.
8.
Install the gasket and strainer bowl onto the
strainer body, and hand tighten the bowl (
9.
Rotate the handle of the pump-shutoff valve 90°
clockwise to the
OPEN
position (
Cleaning the Sprayer Nozzle
Service Interval:
After each use
1.
Rotate the nozzle cap 90° counterclockwise and
remove the cap from the nozzle body (
45
Summary of Contents for 34215
Page 75: ...Schematics g027149 Electrical Schematic Rev A 75...
Page 76: ...g027148 Electrical Diagram Rev A 76...
Page 77: ...g033525 Sprayer System Schematic Rev A 77...
Page 78: ...Notes...
Page 80: ......