![Toro 30069 Operator'S Manual Download Page 38](http://html1.mh-extra.com/html/toro/30069/30069_operators-manual_1133119038.webp)
Figure 49
1.
Bellcrank
3.
Switch mounting bracket
2.
Bolts and nuts
4.
Switch body
Hydraulic System
Maintenance
Servicing the Hydraulic
System
Checking the Hydraulic Fluid
Service Interval:
After the first 8 hours
Every 25 hours
Fluid Type: Mobil 1 15W-50 synthetic motor oil or
equivalent synthetic oil.
Important:
Use oil specified or equivalent. Other
fluids could cause system damage.
Hydraulic System Oil Capacity: 77 oz. (2.3 l)
Note:
There are two ways of checking the hydraulic oil.
One is when the oil is warm and one is when the oil is
cold. The baffle inside the tank has two levels depending
if the oil is warm or cold.
1. Position machine on a level surface.
2. Disengage the power take off (PTO) and shut off
the engine.
3. Wait for all moving parts to stop before leaving the
operating position and then set the parking brake.
4. Clean area around cap and filler neck of hydraulic
tank (Figure 50).
Figure 50
1.
Cap
3.
Cold fluid level-full
2.
Baffle
4.
Hot fluid level-full
5. Remove cap from filler neck. Look inside to check if
there is fluid in the reservoir. (Figure 50).
6. If there is no fluid, add fluid to the reservoir until it
reaches the cold level of the baffle.
7. Run the machine at low idle for 15 minutes to allow
any air to purge out of the system and warm fluid.
Refer to Starting and Stopping the Engine.