26
3. MACHINE WON’T DISPENSE WATER
1. First, when this issue occurs, check the solution tank sight gage for water level. If empty, fill the tank with
cleaning solution.
2. Check the solution flow adjustment knob and ensure that the knob is adjusted to the solution flow level
you desire.
3. If there is solution in the sight gage and the solution flow adjustment knob is properly positioned, then
the filter is likely clogged with debris and needs to be cleaned. Start by draining the solution tank. Unscrew
the inline filter, located on the underside of the unit between the wheels and the casters, and clean out the
debris. Once clean, re-attach the filter and tighten it until snug. Ensure the screen filter element is aligned
properly with the body of the filter during reassembly. Fill the solution tank and check for solution flow. If
solution is flowing, you’ve identified the issue and you can return to cleaning.
4. Check the wire connections to the valve.
If none of the actions listed above fix the solution flow, contact your distributor or Tornado for technical
support.
Sight gage hose
Inline filter screen
Inline filter cap
Sight gage hose
3
4
Solution flow adjustment knob and
wire connections
2
Check sight gage hose for
solution level
1
Summary of Contents for Floorkeeper 28 OB/99128OB