22
Should the pad or brush show ample wear and have reached their
replacement point, simply discard the pad or brush and replace it at the
beginning of your next shift. Brushes should be replaced when the bristle
length reaches 3/4 in (19 mm).
Alternatively, if not worn out, you can extend the life of your pad driver,
pad or brush by rinsing out any captured debris or sediment and then
hanging it to dry between shifts - a simple step that can lower your cost
to clean.
PERIODIC MAINTENANCE
CHANGING BATTERIES
To change the batteries in your unit, move the machine to an area with a level surface, turn off the power
switch and remove the key.
1.To access the battery compartment, tilt the recovery tank to the fully open position.
2.
Using proper open-ended wrench, disconnect the main ground cable first and secure terminal away from
the batteries. Disconnect main positive cable and secure terminal away from the batteries. Loosen both
terminals on jumper cable and remove. Attach a suitable battery lifting device and lift the batteries from the
machine.
3. Reverse the order of the instructions above to install new batteries by orienting and connecting the
batteries as shown in the Battery Connection Diagram. After installation is complete, be sure to charge your
batteries before operating the machine.
NOTE: If changing battery types from wet, lead acid to AGM or vice versa, see Machine Preparation section
for instructions on setting the dip switches on your machines battery charger before beginning the charge
cycle to avoid damaging or undercharging your batteries.
WARNING:
Batteries are a potential environmental hazard. Consult a battery supplier for safe disposal
methods.
WARNING:
Wear protective gloves and eye protection when handling batteries or battery cables.
Avoid contact with battery acid.
WARNING:
Disconnect battery connections before working on the machine.
WARNING:
Short-circuiting or accidentally connecting battery posts or other metallic parts of the
machine with a metal or conductive tool can cause serious personal injury. Use proper
tools and take precautions to not accidentally short circuit battery terminals.
PERIODIC MAINTENANCE
CHECKING THE ISOLATORS ON YOUR 28 OB ORBITAL UNIT
Your orbital scrubber is equipped with an hour meter that is located on the upper control panel.
After 300 hours, it is time to check the eight isolators located in the scrub head of the unit.
Battery Connection Diagram
2
Fully open position allowing access to
battery compartment
1
Starting at the front corners of the pad,
pull it down and off of the driver pad
1
Summary of Contents for Floorkeeper 28 OB/99128OB
Page 3: ...3 NOTES...