15
Weekly-
CAUTION: Never test the strength of the
battery unless it is fully charged and cool.
Check the battery cells with a hydrometer.
Monthly-
1
Lubricate brush and squeegee lift mechanisms
with light oil.
2
Check for wear or damage of clutch plate,
brushes, pads, or squeegee blades.
3
Clean all battery terminals.
4
Check all electrical connections and tighten if
any are loose.
5
Clean entire machine with all purpose cleaner.
Problem: Solution is not being picked up
Vacuum motor is not running
Vacuum filter is clogged
Recovery tank is full
Squeegee or vacuum hose is clogged, broken or
disconnected
Bad seal at tank cover, vacuum motor or
squeegee
Worn or misaligned squeegee blades
Incorrect squeegee pressure
Squeegee swing arm mechanism not functioning
properly
Problem: Squeegee is leaving streaks
Debris is on blade
Blades are torn or damaged
Floors are not properly swept before cleaning
Problem: Solution is not feeding or turning
off properly
Clogged hose or valve
Problem: Batteries are not holding a charge
Batteries need to be replaced
High current draw from high brush pressure
Charger needs servicing
Battery is run down
Problem: Floors are not being scrubbed,
Stripped or buffed properly
Brush motor is not working
Excessive pad or brush wear
Going too fast over dirty spots
Inadequate solution feed
Inadequate cleaning procedure
Summary of Contents for 99105A