PowerSlide 27
ENGLISH
LOGIC A: AUTOMATIC
GATE STATUS
PULSES
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens. Closes after
the pause time
Opens partially.
Closes after the
pause time
No effect (OPEN
disabled)
No effect (OPEN
disabled)
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
WHEN OPENING
No effect
No effect
Stops
§ -
-
oP
No effect
Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Resets pause time Resets pause time Stops
No effect
Resets pause time
(OPEN disabled)
Resets pause time
(OPEN disabled)
No effect (OPEN
disabled)
WHEN CLOSING
Opens
Opens
Stops
No effect (memo-
rizes OPEN)
§ -
-
Ph
Stops. Opens when
disengaged
Reverses to open-
ing for 2 seconds*
STOPPED
Closes
Closes
No effect (OPEN
disabled)
No effect
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
LOGIC AP: AUTOMATIC STEP-BY-STEP
GATE STATUS
PULSES
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens. Closes after
pause time
Opens partially;
closes after pause
time
No effect (OPEN
disabled)
No effect (OPEN
disabled)
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
WHEN OPENING
Stops
Stops
Stops
§ -
-
oP
No effect
Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Stops
Stops
Stops
No effect
Resets pause time
(OPEN disabled)
Resets pause time
(OPEN disabled)
No effect (OPEN
disabled)
WHEN CLOSING
Opens
Opens
Stops
No effect (memo-
rizes OPEN)
§ -
-
Ph
Stops. Opens when
disengaged
Reverses to open-
ing for 2 seconds*
STOPPED
Closes
Closes
No effect (OPEN
disabled)
No effect
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
LOGIC S: AUTOMATIC SAFETY
GATE STATUS
PULSES
SAFETY DEVICES
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
EDGE
CLOSED
Opens. Closes after
pause time
Opens partially.
Closes after pause
time
No effect (OPEN
disabled)
No effect (OPEN
disabled)
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
WHEN OPENING
Closes
Closes
Stops
§ -
-
oP
No effect
Stops. Opens when
disengaged
Reverses to closing
for 2 seconds
OPEN IN PAUSE
Closes
Closes
Stops
No effect
Closes after 5 sec.
(OPEN disabled)
Closes after 5 sec.
(OPEN disabled)
No effect (OPEN
disabled)
WHEN CLOSING
Opens
Opens
Stops
No effect (memoriz-
es OPEN)
§ -
-
Ph
Stops. Opens when
disengaged
Reverses to opening
for 2 seconds*
STOPPED
Closes
Closes
No effect (OPEN
disabled)
No effect
No effect
No effect (OPEN
disabled)
No effect (OPEN
disabled)
9. OPERATING LOGICS
L
i
In logics A, AP and S, the maintained commands OPEN A and OPEN
B prolong the OPEN IN PAUSE status until they are disabled (E.g. by
TIMER). The effects on the other active inputs are shown in brackets.
Summary of Contents for POWERSLIDE
Page 1: ...POWERSLIDE GEBRAUCHSANLEITUNG D 913002 26 6 50 01 2018...
Page 2: ......
Page 31: ...POWERSLIDE INSTRUCTION MANUAL GB...
Page 32: ......
Page 61: ...POWERSLIDE GEBRUIKSAANWIJZING NL...
Page 62: ......
Page 91: ...PowerSlide 31...