11: TROUBLESHOOTING
©Tormach® 2020
Specifications subject to change without notice.
Page 61
UM10538: Tormach AF50 Autofeed Bandsaw (Version 0320A)
For the most recent version, see tormach.com/support
You May Need
To...
Probability
How-To Steps
Need More?
Replace the
coolant pump.
Low
Verify that the:
l
Main motor is running
l
The blade is running
WARNING!
Crush Hazard: Moving parts
can entangle, pinch, or cut you, causing
death or serious injury. While operating
the machine, you must keep your hands
away from the blade.
l
Coolant switch is in the
ON
position
Then, use a digital multimeter to measure AC voltage
at wires 208 and 102/N at the operator panel.
WARNING!
Electrocution Hazard: When
servicing the machine from inside the
operator panel, always use caution. Even after
you've powered off the machine, electronic
devices in the operator panel may retain
dangerous electrical voltages. Only qualified
electrical machinery technicians should
perform maintenance or troubleshooting
procedures inside the operator panel while
power is still on.
If there's no voltage, replace the coolant pump.
For information, see "Electrical
Examine the
wiring.
Low
Examine the coolant pump's wiring for breaks,
disconnection, or corrosion. If necessary, replace or
repair the wires.
For information, see "Electrical