2 - Operation and maintenance
TO320 M - EN - Ed. 04.09
PROBLEM
SOLUTION
The motor protection thermal cut-out switch acts
thereby stopping the machine.
• Check to make sure the switch setting is cor
-
rect; set the correct activation threshold, if
necessary.
• Check the electric motor connections, and reset
if necessary.
• Check the state of the electric motor using the
instruments meant for the purpose and replace
it, if necessary. To carry out the operations
described above, follow the safety regulations
concerning electrical equipment. Check to
make sure large sized particles do not allow
rotation of the rotor.
• Remove the material that caused the block,
after having created the appropriate safeties:
make sure the machine is disconnected from
the power supply.
• Locate the material that caused the block, re
-
move it, restore the machine to the operating
position and restart it.
• Check to see if power supply is present.
Valve block
• Check to see if there is a block or an object
that prevents rotation of the rotor. If this is the
case, disconnect power supply and remove the
object.
POSSIbLE PRObLEMS
16.
Minor problems can be solved without consulting a specialist. A list of the most common problems
with the possible causes and remedies is given below.
Summary of Contents for VDC 200
Page 1: ...VDC Double dump valve EN TO320 EN Ed 04 09 ...
Page 7: ...TECHNICAL CATALOGUE TO320 T EN Ed 04 09 1 VDC Double dump valve EN ...
Page 24: ......
Page 25: ...VDC Double dump valve EN OPERATION AND MAINTENANCE TO320 M EN Ed 04 09 2 ...
Page 66: ......
Page 67: ...SPARE PARTS CATALOGUE VDC Double dump valve EN TO320 R EN Ed 04 09 3 ...
Page 76: ...10 3 Spare Parts Catalogue TO320 R EN Ed 04 09 Plate 2 Counterweight 2 1 2 4 2 3 5 ...