Keep the connection surface free of any dirt or oils.
Follow the instruction below when storing the modules.
A wrong use may cause the damage to the module.
6. Air inject should be located just beneath the bottom nozzle of the module to inlet air
completely to the module. Also, a check valve is necessary to the air piping to avoid water
reverse flow (see Fig. 3).
Make sure air tubes or connected pipes are properly
fixed. Otherwise, the tubes or connected pipes may be
blown away or behave violently during air-scrubbing.
7. Make sure that the module is installed vertically.
If the module is not installed vertically, the effect of the
air-scrubbing would be reduced, and an effective
filtration will be impaired.
Fig. 3. Typical example of the air pipe installation