AC equipment cannot be connected directly to the module. It is necessary to use a special relays or other methods, which are in
compliance with electrical safety requirements.
When controlling devices from the AC network, it is necessary to follow all electrical safety requirements.
3.2
Inputs
The module GTalarm3 has:
7 burglary zones.
Can be expanded up to 32.
4 analog inputs (In1...In4 (0-30V))
for analog sensors connection. Or can be used as security system‘s zones with selectable type:
NC/NO/EOL/EOL+TAMPER.
3 programmable selectable analog inputs (I/O1, I/O2, I/O3 (0-30V/0-20mA))
for analog sensors control or using as security
system‘s zone with selectable type: NC/NO/EOL/EOL+TAMPER
3 programmable digital inputs (D1...D3(Max voltage 3.3V))
used for:
o
Dallas 1-Wire Bus.
To connect temperature sensors DS18b20 or iButton key DS1990A,
o
Aosong 1-Wire bus Humidity Sensor
AM2302, DHT22, AM2305, AM2306,
o
Wiegand interface
DATA0/ DATA1, RFID reader, Keyboard.