(6) DURATION:
Buzzer noise and event record duration of an alarm, from 1 sec to 99 seconds. The default value is
5 seconds.
(7) ALARM OUTPUT:
The setting of alarms which are
NONE
and
1,
where
1
means the alarm is enabled.
(8) ALARM EMAIL:
Select “
YES
” for sending an email when alarm occurs. The email address can be set in the
NETWORK SETUP MENU
.
(9) BUZZER:
Alarm buzzer. ( The Default is on )
ENABLE
: To enable an alarm buzzer.
DISABLE
: To disable an alarm buzzer.
(10) ALARM NETWORK:
YES:
Enable alarm network.
NO:
Disable alarm network.
(11) MAIN MON:
Display on a main monitor when an alarm occurs.
NO CHANGE:
Nothing changes on the display in the main monitor when an alarm occurs.
FULLSCREEN:
A full screen will pop up when an alarm occurs.
(12) CALL MON:
Display on a call monitor when an alarm occurs.
NO CHANGE:
Nothing changes on the display in the call monitor when an alarm occurs.
SEQUENCE:
Display in the sequence mode when an alarm occurs.
ACTIVE CAMERA:
Display the active camera in full screen mode to the call monitor.
(5) PTZ PRESET:
Select PTZ PRESET from “001” to “255”, so that when Alarm occurs, speed dome will turn to this
preset position for event recording. This function improves surveillance quality of an alarm event. If
you wis disable this function, please simply select “OFF”.
21