16
Without a properly installed safety reversal system, person (particularly small children) could be SERIOUSLY INJURED
or KILLED by a closing gate.
*Too much force on gate will interfere with proper operation of safety reversal system.
*NEVER
increase force beyond minimum amount required to close gate.
*NEVER use force adjustments to compensate for a binding or sticking gate.
*
If one control (force or travel limits) is adjusted, the other control may also need adjustment.
* After ANY adjustments are
made, the safety reversal system MUST be tested. Gate MUST BE TESTED. Gate MUST
reverse on contact with a rigid object.
The opener is equipped with an obstruction sensing feature. If the gate encounters an obstruction the opener will
automatically reverse direction and stop. Based on the length and weight of the gate it may be necessary to make force
adjustments. The force adjustment should be high enough that small objects such as branches or wind will not cause
nuisance interruptions but low enough to prevent serious injury to a person or a vehicle.
NOTE:
You may need to increase the stall force in cold weather due to increased resistance from
gate hinges. The gate opener’s opening/closing force is adjusted automatically according to stall force
adjustment.
Press the “FUNC” button to store the data when the open interval is set. The Digital Display will indicate “P4”.
Now Open Interval Set is finished.
5. Set the Close Interval between Master and Slave Gate
When the Digital Display indicates “P4”, the gate opener is on the Close Interval between Master/Slave Gate
Setting.
The close interval can be adjusted by pressing the “INC” and “DEC” buttons respectively. The Digital Display
will show “0”-“9”, which indicates the interval time ”0” means the Master and Slave gates close
simultaneously. ”1” means the Slave Gate starts to close 1 second before Master gate starts to close. Maximum
close interval is 9 seconds. Each time you press and release the “INC” button, the figure increases by 1, and the
Slave gate starts to close 1 more second earlier. Each time you press and release the “DEC” button, the figure
decreases by 1, and the interval decreases by 1 second.
(Factory set is 3 seconds)
Press the “FUNC” button to store the data when the close interval is set. The Digital Display will indicate “P5”.
Now Close Interval Set is finished.
6. Adjust the Obstruction Sensitivity/Stall Force
When the Digital Display indicates “P5”, the gate opener is on the Stall Force Adjustment.
6-a Adjust Stall Force of Gate Opener 1
Now we adjust the stall force of gate 1
The stall force of gate opener1 is adjusted by pressing “INC” and “DEC” buttons respectively. The Digital
Display will show “1”-“9” which indicates the stall force levels. “1” means the minimum force, and “9” is the
maximum force. Each time you press and release the “INC” button, the figure increase by 1, and the force
increases to a higher level. Each time you press and release the “DEC” button, the figure decreases by 1, and
the force decreases to a lower level. Press “FUNC” to store the data. The Digital Display will indicate “P6”.
Now stall force of gate opener 1 is finished.
(Factory set is Level 3)
6-b Adjust Stall Force of Gate Opener 2
When the Digital Display indicates “P6”.you can adjust force of gate opener 2.
Please perform the same procedure as gate opener 1 (6-a).
Press the “FUNC” button to store the data when stall force of gate opener 2 is set. Then “P7” will be shown on
the Digital Display.
7. Adjust the Max Motor Running Time (MRT) of the MOTOR for gate opener
The maximum running time of the MOTOR can be set to make the motor stop running after a specified period