background image

 

Thank you for purchasing our sliding gate opener. We are sure that the products will be greatly satisfying as 
soon as you start to use it. 
The product  is  supplied with  a  user’s manual  which  encloses installation  and  safety  precautions.  These 
should be read carefully before installation and operation as they provide important information about safety, 
installation, operation and maintenance. This product complies with the recognized technical standards and 
safety regulations. 

General Safety 

  WARNING! An incorrect installation or improper use of the product can cause damage to persons, 

animals or properties. 
• Scrap packing materials (plastic, cardboard, polystyrene etc.) according to the provisions set out by current 
standards. Keep nylon or polystyrene bags out of children’s reach. 
•  This  product  was  exclusively  designed  and  manufactured  for  the  use  specified  in  the  present 
documentation.  Any  other  use  not  specified  in  this  documentation  could  damage  the  product  and  be 
dangerous. 
• The factory declines all responsibility for any consequences resulting from improper use of the product, or 
use which is different from that expected and specified in the present documentation. 
• Do not install the product in explosive atmosphere. 
•  The  factory  declines  all  responsibility  for  any  consequences  resulting  from  failure  to  observe  Good 
Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation 
which might occur during use. 
• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect 
any buffer batteries, if fitted. 
• Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance 
equal to or greater than 3,5 mm. 
• Make sure a residual current circuit breaker with a 30mA threshold is fitted before the power supply mains. 
• Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all 
system components provided with an earth terminal. 
• Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any 
danger caused by squashing, conveying and shearing. 
• Position at least one visible indication device (Alarm lamp), and fix a Warning sign to the structure. 

 

• The factory declines all responsibility with respect to the automation safety and correct operation when 
other supplier’s components are used. 
• Only use original parts for any maintenance or repair operation. 
• Do not modify the automation components, unless explicitly authorized by the factory. 
• Instruct the product user about the control systems provided and the manual opening operation in case of 
emergency. 

Summary of Contents for DK1000

Page 1: ...0a DK1000 S Y T Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the battery Periodic...

Page 2: ...allation Overview 6 Installation of the Opener 6 Manual Operation 7 Fit The Rack 8 Installation of the Magnets 9 Connecting of AC Main Power Supply 9 Connecting of the Batteries Solar Panels Solar Con...

Page 3: ...e factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation...

Page 4: ...table for use The gate should be mounted and moved freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications ta...

Page 5: ...4 Parts List Extra Parts Rev 20a...

Page 6: ...TOPENS Store Technical Specifications Features Specifications Model DK1000 S Y T Power supply 110V 120V 60Hz or 220 240V 50Hz Motor voltage 24VDC Absorbed power 350W Gate moving speed 20 cm s 8 in s M...

Page 7: ...ble auto close none 30 60 90 seconds Built in max Motor Running Time MRT for multiple safety protection 90 seconds Reliable electromagnetism limit for easy adjustment Can be equipped with a wide range...

Page 8: ...before pouring concrete Remember that cable conduits have to pass through the hole in the base plate 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and perf...

Page 9: ...of rack section on the gear of opener as a temporary support Make rack level and mark the rack s mounting holes four holes for light duty or six holes for heavy duty on the gate 4 Fit the rack by sel...

Page 10: ...The magnets should be 20 30mm away from the Limit Switch Box If it is too near or too far the switches will fail to work Adjust the position of the magnets until the positions of the opening and closi...

Page 11: ...are chosen as the power source Marine or Automotive Type Battery is required The batteries should be waterproof type or be placed in water proof circumstance 3 2 PCS 12VDC batteries can be connected...

Page 12: ...condition and accessories needs which we can calculate the configuration of the solar panel and the batteries Please connect the batteries the solar panels solar controller refer to the following illu...

Page 13: ...button should be wired to the 16 and 17 terminals No matter the polarity The gate operator works alternately by pressing the button open stop close stop open 6 Exit Wand optional The BLACK wire of the...

Page 14: ...pad should be connected into the 17 terminal NOTE Using of the photocell exit wand keypad and external receiver would cause the battery exhausted quickly Big capacity of batteries and big power of sol...

Page 15: ...te the gate opener to run for a complete opening cycle and a complete closing cycle to get the full opening time and the full closing time You would achieve the soft stop in your next opening closing...

Page 16: ...ition to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will stop or reverses very easy by itself while there is little obstruction or resistance such as s...

Page 17: ...on refer to more details in our TOPENS sliding gate opener manual So it is must program button A with sliding gate opener while you may program either C button or D button with TOPENS swing gate opene...

Page 18: ...wires of the motor from terminal 1 and 2 Connect the wires to 24V battery directly the motor should run and then exchange the wires the motor should run in the opposite direction If the motor runs in...

Page 19: ...se note the two limit magnets are different one is N pole and another is S pole Please try to exchange the two magnets 2 Please try to exchange the limit switch wires CL close and OP open 3 Maybe the...

Page 20: ...e do not hesitate to contact us E mail support topenstool com Kindly include your Product Model Purchasing Date Site Order and your contact information All your concerns will be replied within 24 hour...

Reviews: