12
Use a 2-core cable to connect the
“- ~”
terminal of the photocell’s emitter to the “19” terminal, the
“+ ~”
terminal to the “18” terminal. Also the
“- ~”
and
“+ ~”
terminals of the photocell’s receiver should be
connected to the “19” and “18” terminals in parallel.
Use another 2-core cable to connect the
“NC”
terminal of the receiver to the “13” terminal, the
“COM”
terminal to the “12” terminal.
5. Push Button (optional)
The push button should be wired to the “16 and “17” terminals. No matter the polarity. The gate operator
works alternately by pressing the button (open-stop-close-stop-open).
6. Exit Wand (optional)
The
BLACK
wire of the exit wand should be connected into the “14” terminal.
The
BLUE
wire of the exit wand should be connected into the “15” terminal.
The
RED
wire of the exit wand should be connected into the “18” terminal.
The
GREEN
wire of the exit wand should be connected into the “19” terminal.
The sensitivity adjustment board should be wired to the
GREEN
wire and the
YELLOW
wire of the wand. No
matter the polarity.