![Topcon MR-2 Operator'S Manual Download Page 57](http://html.mh-extra.com/html/topcon/mr-2/mr-2_operators-manual_1128744057.webp)
Updating Firmware
48
P/N: 1011907-01
Configur
ation
Updating Firmware
Updating firmware on the receiver requires an Ethernet connection. If your unit has two B125 boards, each
board requires an update, and each board has a different IP address. The IP address for the main board is
192.168.0.9. The IP address for the auxiliary board is 192.168.0.10. Follow the below procedure for both
boards.
1. Download the latest firmware build to your PC.
2. Open TRU and click
Device
Application Mode
Receiver Managing
.
3. Connect to the receiver using an Ethernet connection (Figure 59).
Figure 59: TRU – Ethernet Connection
4. Click
Connect
.
5. Once connected, click
Device
Application Mode
Firmware Loading
.
Do not unplug the power or Ethernet connection during the firmware update process.
See “Connect to TRU Using Ethernet” on page 25 for more information.