An electric shock could cause serious injuries or potentially even deadly accidents.
Do not touch any live part of the machine (inside or outside) when it is plugged in because they are connected to the welding
circuit.
Do not touch the torch or and the earth clamp at the same time.
Always wear dry clothes which are in good condition in order to be isolated from the welding circuit. Always wear insulated shoes, regardless of the
environment in which you work in.
PRECAUTION FOR USE
Never wrap the welding leads around your body.
Do not use the torch to move the welding power source or wire feeder.
The torch must be fully uncoiled to prevent overheating.
Switch off the generator after the torch is cooled and before each maintenance and before replacing or control wearing parts.
Regularly check the condition of the torch. If damaged, the torch must be replaced.
GENERAL DESCRIPTION
SPECIFICATIONS
The MIG 15 / MIG 25 / MIG 36 / TT120 / PT120 torches are intended to the manual MIG / MAG welding processes.
TECHNICAL SPECIFICATIONS
Component
063754
063761
Component
063778
063785
063792
063808
Component
Part number
71846
71847
71848
71866
71879
C71453
C71454
53277
C71391
71392
Designation
MIG 15
MIG 25
MIG 36
TT120
PT120
Process
MIG / MAG
(GMAW / FCAW)
MIG / MAG
(GMAW / FCAW)
MIG / MAG
(GMAW /
FCAW)
NO GAS MIG
MIG/MAG
Guidance method
Manual
Manual
Manual
Manual
Manual
Rated current
Corresponding
duty cycle
150 A
35%
180 A
60%
230 A
60%
340 A
60%
120 A
35%
120 A
35%
Rated voltage
≤113 V
≤113 V
≤113 V
≤113 V
≤113 V
Cooling mode
Air
Air
Air
Air
Air
Connections
EURO
EURO
EURO
Fixed
Fixed
Gas protection
150 A CO2 /
120 A Mix
180 A CO2 /
150 A Mix
230 A CO2 /
200 A Mix
340 A CO2 /
300 A Mix
-
120 A CO2 /
100 A Mix
Gas flow
10-18 L/min
(2.64/4.75 US
gpm)
10-25 L/min
(2.64/6.60 US
gpm)
10-25 L/min
(2.64/6.60 US gpm)
10-25 L/min
(2.64/6.60 US
gpm)
-
6-15 L/min
Contact tube
Ø 0.8
Steel
Ø 1.0
Steel
Ø 0.8
Steel
Ø 0.8
Alu
Ø 1.2
Alu
Ø 0.8
Steel
Ø 1.0
Steel
Ø 1.0
Steel
Ø 1.0
Steel
Ø 1.0
Alu
Ø 1.2
Steel
Ø 1.2
Alu
Ø 0.9
Steel
Ø 0.8
Steel
Cable length
3 m
3 m
3 m
3 m
4 m
4 m
3 m
4 m
3 m
2.5m
2.35m
2.2 m
2.4m
Cross section
14 mm²
16 mm²
25 mm²
42 mm²
10 mm²
10 mm²
Switch trigger
voltage
10 V
10 V
10 V
10 V
10 V
Functionning
temperature
- 10
+40°C
Storage
temperature
- 10
+55°C
Applied standard
IEC 60974-7
IEC 60974-7
IEC 60974-7
IEC 60974-7
IEC 60974-7
SET UP
TORCH CONNECTION REQUIREMENT
MIG 15-25-36
The generator must be switched off.
Insert the torch connector (A) in the
female connector (E) and screw the
part B. Make sure the torch is tight
enough.
To remove the torch, unscrew as
shown below.
TT120 - TP120
The generator must be switched off.
1. Open the cover.
2. Unscrew the 4 screws (framed in black).
3. Disconnect the cables and remove the
torch.
4. Replace the new lamp.
5. Reconnect in the same way and then
screw it back on.