![Top Gun 3200 AC/DC TIG Operation Manual Download Page 9](http://html1.mh-extra.com/html/top-gun/3200-ac-dc-tig/3200-ac-dc-tig_operation-manual_1127667009.webp)
TOPGUN 3200 AC/DC TIG USER MANUAL
9
percentage for a 10-minute work cycle. Determines the time enabling the device to work under
maximum / set load. When the duty cycle is exceeded, the device parameters drop temporarily or the
overload protection switches on.
The operator must wait a certain amount of time to cool down the device, depending on
degree of device overload and external conditions it may take a few to several minutes.
Efficiency
4
0
%
4 minutes of continuous operation of the device under maximum / set load.
Efficiency
60
%
6 minutes of continuous operation of the device under maximum / set load.
Efficiency 100%
uninterrupted operation of the device under maximum / set load.