ToolkitRC
2019
38
6. Manually calibrate the voltage.
Under power off state, press and hold the jog switch
without releasing it,and connect the input power to
the power source. The system will enter the manual
calibration voltage function. Use a voltmeter to
measure the actual voltage of each battery, move
the cursor to the corresponding voltage value, and
modify the voltage value to match the voltmeter
value for calibration. After the calibration is
completed, move the cursor to save, short press
once, the buzzer sounds once and the save is
successful. Exit or Turn off device
7, Supplement
When the lithium battery is fully charged, the
prompt "fast charging has ended".If the battery is
not removed, constant voltage trickle charging will
be performed automatically to bring the battery to
the even more full state.
Summary of Contents for M8
Page 23: ... ToolkitRC 2019 23 ...