12
/
26
12
switch for the first time, current up to
standard
welding
current
while
releasing the torch switch. Press the
torch switch again after welding is
finished, and then welding current
begin down to end-ARC current and
retain it. The welding machine stops
outputting current after releasing torch
switch for the second time. This is
suitable for long time welding.
12. MIG/ARC:
This is to select MIG or
MMA welding; Turn up is MIG welding,
turn down is MMA welding.
13. Crater on/off:
This is to select crater
function or not.
14. Gas Checking:
This is to select Gas
checking beforehand or not
.
15.
MIG Torch connector:
when
you chose MIG welding mode , please
plug the welding plug with cable to the
MIG control socket and plug the
ground cable to socket
16.
“-“Ground cable connector:
Plug
the ground cable to this connector and
clamp the other end to the work piece.
17.
“+” MMA cable connector:
when you
chose ARC welding mode(, please
plug the MMA welding plug with cable
to the MIG control socket and plug the
ground cable to socket
Assembly the wire feeder
Note:
When installing wire of a different size or composition, maybe you will also need to
change wire settings, and, possibly, install a gas cylinder.
1. Important:
Securely hold onto the end of the Welding Wire and keep tension on it
during the following steps. If this is not done the welding wire will spring back and
creating a tangled “bird’s nest” and resulting in wasted wire.
2.
Hold the Welding Wire securely while you cut enough Wire off the end of the Spool to
remove
all bent and crimped Wire. Make sure the cut end has no burrs or sharp edges
(cut again, if needed).
3.
Loosen and lower the Tension Adjusting Knob (1a) on the Wire Feed Assembly. Then,
Tension
Adjusting
Knob (1a)
Wire
Feed
Leader (3a)
Swing
Arm (2a)
Manual wire feeder
(4a)
Wire feed
rolls (5a)
Summary of Contents for MIG-200