![TOOLCRAFT 1428451 Operating Instructions Manual Download Page 27](http://html.mh-extra.com/html/toolcraft/1428451/1428451_operating-instructions-manual_1126785027.webp)
27
7. Cleaning and maintenance
a) Cleaning
Before cleaning, the product must be disconnected from the mains and completely cooled to ambient temperature.
The "conical nozzle" (11) must not be dirty and must be cleaned with a rag or brush. The product may be cleaned
with a dry cloth.
b) Bearing
Always place or put the product onto a level, fire-proof surface after use until the hot product parts have cooled off.
The storage site must be dry and have a moderate temperature. For this, observe the storage conditions in the
technical data.
8. Disposal
The product does not belong in the household waste.
Dispose of the product according to the applicable statutory provisions at the end of its service life.
9. Technical Data
Operating voltage ..............................230 V/AC (50 Hz)
Output ................................................2000W
Temperature max. ..............................650 °C
Protection class .................................Protection class II
Operating conditions .......................... -20 °C to +50 °C, 0% to 60% relative humidity, non-condensing
Storage conditions .............................- 20 °C to +60 °C, 0% to 60% relative humidity, non-condensing
Dimensions min. (L x W x H) .............900 x 170 x 70 mm
Dimensions max. (L x W x H) ............1150 x 170 x 70 mm
Weight ...............................................1.25 kg
Length of mains cable .......................approx. 50 cm