![TOMARK Viper SD-4 RTC Maintenance Manual Download Page 90](http://html.mh-extra.com/html/tomark/viper-sd-4-rtc/viper-sd-4-rtc_maintenance-manual_1125579090.webp)
TOMARK, s.r.o.
Airplane Maintenance Manual
Chapter 20 Standard Practices-Airframe
Page 90
Issue: 11.AUG 2016
Air
Hose
Hose clamps
Brake
Hose
Fitting, joint with
incise ring and
interposition hose
(Kašpar)
20-10-04 Bowden Cables
Removal
▶
Note position of cable tie.
▶
Remove cable tie.
▶
Disconnect Bowden cable from actuator arm.
▶
Remove firewall seal from firewall penetration.
▶
Unscrew firewall penetration plastic grommet.
▶
Loosen the counternut of control knob.
▶
Pull out the Bowden cable.
Installation
▶
Install in reverse sequence of removal.
▶
Seal firewall penetration with PR 812 sealant.
▶
Check correct travel. Adjust travel if necessary.