Scheduled Inspection
(50 h)
100 h/
annual
as
specified
Perform Full Throttle Test Check.
○
○
○
2
Check brakes at full throttle
○
○
○
2
Check Idle RPM (refer to ROTAX 912 Operators Manual).
○
○
○
1
Fuel pressure within limit over complete RPM range both
pumps individual and in combination.
○
○
○
1
Check battery and power generation.
○
○
○
1
Install engine cowlings
○
○
○
1
Perform maintenance check flight according to
○
○
1
Make appropriate aircraft and engine logbook entries for
scheduled power plant service.
○
○
○
1
Ensure all Maintenance Record log-book entry’s required are
complied with before the aircraft return to service.
○
○
○
1
File all documents e.g. inspection report, ground run report
Forms and tags in aircraft history file.
○
○
○
1
05-20-02 Lubrication Chart
Three types of lubricants are used which are recommended:
LPS1 – Non-fat lubricant
Basic characteristics: dissolve fat and oils repels oil, dust and
sediments
creates dry, thin lubricated layer quickly penetrates and removes
moisture loosens rusted and seized parts; offers short term corrosion
protection safe for all surfaces
LPS2 – Strong industrial lubricant
Basic characteristics: creates everlasting thin oil layer; usage on outer
and inner devices; increased corrosion protection; expels moisture;
1
First 25 hours of operation for new or overhauled engine