KOLLERCRAFT
LIMITED WARRANTY
KOLLERCRAFT a Division of Koller Enterprises,
Inc. warrants this aquarium product to be free
from defects in material and workmanship under
normal use and service and according to the
provisions as specified in the accompanying
assembly and operating instructions, for a period
of 2 years from date of purchase.
This
warranty
does
not
cover
and
KOLLERCRAFT is not liable for the cost of
repair or replacement of parts which have been
subject to misuse, negligence, accident, improp-
er installation, damage during shipment or han-
dling, normal deterioration due to wear and
exposure or defects caused by unauthorized
parts or modification.
UNDER
NO
CIRCUMSTANCES
WILL
KOLLERCRAFT
BE
LIABLE
FOR
ACCIDENTAL OR CONSEQUENTIAL DAM-
AGES, INCLUDING BUT NOT LIMITED TO
LOSS OF PROPERTY OR EQUIPMENT.
Some states do not allow the exclusion or
limitation of incidental or consequential
damages, or limitation on how long an im-
plied warranty lasts, so the above limitations
or exclusions may not apply to you. This
warranty gives you the legal rights, which
vary from state to state.
IF ANY COMPONENTS ARE
DAMAGED OR MISSING
DO NOT RETURN TO THE STORE
email [email protected]
Warranty Repairs or Replacement
FOR HELP OR COMMENTS
or
(800) 545-1344
3. Assembling Filter Media
4. Filter Assembly
TOM items and components are
registered
trademarks
of
Koller
Enterprises, Inc. and its affiliates.
Manufactured
and
distributed
by
KOLLER CRAFT Fenton, MO 63026 USA
a) Partition
b) Bio-Cylinders
c) Filter Media
d) Power Unit
Place the Canister in the Hanger and position on the
frame of the aquarium.
Open Water Fill Cap (if too tight use needle-nose
pliers to remove cap) and fill Canister with water to
top of opening (a).
Wait 5 minutes. The Filter Media will absorb water
and additional water will be needed to top off the
Canister.
Reinsert the Water Fill Cap, making sure the O-Ring
on the Fill Cap is properly positioned.
Plug AC Adaptor into standard 120V electrical recep-
tacle. Note; do not force polar-
ized plug into non-polarized
receptacle.
Check for leaks to confirm
Canister is properly sealed .
Use of a GFCI (Ground Fault Circuit Interrupter) is
always recommended when using electrical appli-
ances around water.
The Mounting Bracket is removable if you wish to
place the Canister next to the aquarium and not
hang on the tank.
Trouble Shooting-Canister filter not pumping water
Unplug Canister Filter and lift filter, tipping it back
and forth to remove possible trapped air inside the
canister. Plug filter back into electrical outlet.
Check spray bar or water diffuser to confirm water
is flowing.
If still not pumping, unplug the filter from electrical
outlet. Unscrew Fill Cap (see (a) above), turning it
counter clockwise. If difficult to remove, use pliers
to grasp Cap and turn. Fill the canister completely
to the top of the fill hole and replace Fill Cap on
filter. Make sure Fill Cap locks into place, the filter
may not operate properly if Cap is not locked
properly.
5. Priming and Starting Filter
e) Spray Bar
b) Attach
Strainer
Slide two Suction Cups onto the longer
plastic U-Tube (a).
Press the Strainer onto the long-end of the
same Intake Tube (b).
Take one of the Corrugated Hoses and con-
nect the larger diameter end of the Hose to
the short-end of the Intake Tube (c).
Connect the opposite smaller-diameter end
of the Corrugated Hose to the Power Unit
hose connector and tighten the Hose Nut
(d).
Slide two Suction Cups onto the Spray Bar.
Attach elbow connector to Spray Bar.
Take the shorter plastic U-Tube and connect
the Spray Bar with elbow onto one end of
the U-Tube (e).
Take the second Corrugated Hose and con-
nect the large-diameter end to the opposite
end of the U-Tube.
Connect the smaller-diameter end of the
Corrugated Hose and connect to the Power
Unit (out)
,
then tighten Hose Nut.
c) Connect Hose
d) Hose Nut
a) Fill Cap
a) Suction
Cup
Place the Power Unit (d) onto the
Filter Housing and press the Clips
downward to seal the Canister Filter.
Confirm Filter Compartment
Partition is securely in place (a).
Remove Ceramic Cylinders from
plastic bag and place Ceramic
Cylinders in Biological Chamber (b).
Roll Floss/Carbon Media bag and
place in the Media Compartment
(c), then position Media Core Tube
with Power Unit into middle of filter
media and attach Power Unit. Or
wrap filter media around Media
Core Tube and insert into canister
body, snapping clips into place.