23
Operation and display
●
1
st
angle tightening stage
Tighten 1
st
angle tightening of the 1
st
spindle.
When it passes the snug torque, the display
changes to the angle counting.
Upon reaching the set angle, the buzzer goes off
and the blue LED turns on.
Buzzer starts on and off upon reaching 20
degrees from the set angle).
If the tightened angle exceeds the upper limit,
another buzzer goes off and the red LED starts to blink.
After releasing loading, press MEM key to make judgment to see whether the tightened
torque/angle is within the set range (The judgment will be made automatically when auto
memory/reset is set).
- In case of OK: It saves the measured data and proceed to the next counter.
- In case of NG: It inform by the buzzer alarming and the red LED.
Press MEM key again to save this measured data and proceed to the next counter.
* If you would like to delete the data, press C key.
Check the number of spindles (about 0.5 sec)
Tighten 1
st
angle of the 2
nd
spindle.
After completing 1
st
angle tightening for all the number of spindles, it proceeds to
the 2
nd
angle tightening.
●
2
nd
angle tightening stage
Process 2
nd
angle tightening of the 1
st
spindle.
After completing 2
nd
angle tightening for all the number of spindles, the display shows the data
output display.
Blue
Red
Blink