21
After releasing loading, press MEM to make judgment whether the tightened value is
within the set range.
(
When auto memory/reset is effective, the judgment will be made automatically
)
.
・
In case of OK: It saves the measured data and proceed to the next counter.
・
In case of NG: It informs by the buzzer alarming and the red LED.
Press MEM key again to save this measured data and proceed to the next counter.
If you would like to delete the data, press C key.
Check the spindle counter (about 0.5 sec)
Proceeds to 1
st
angle tightening of the 2
nd
spindle.
・
After completing 1
st
angle tightening for
the set number of spindles, it proceeds to
the 2
nd
angle tightening.
●
2
nd
angle tightening stage
Start 2
nd
angle tightening of the 1
st
spindle.
After completing tightening for the set number of spindles, the display changes to the
data output display.
●
Data output
Press MEM key to complete tightening.
(
If the communication cable is
connected, it output 1 data at the same
time).
Memory counter will proceed
to the next tightening.
deg
D-OUT
T 0.0
deg
N・m