Functional Description
05
MODE 1 OPEN-PLAN OFFICE
The luminaire switches itself off once the light lag period has elapsed (between 5 and 30 minutes;
adjustable via remote control unit). Recommended for individual offices.
Once the light lag period has elapsed (between 5 and 30 minutes; adjustable via remote control
unit), the luminaire dims to 20% for 2 hours, after which the luminaire switches itself off. This en
sures ambient light and thus facilitates orientation in the room. Recommended for open-plan
offices without lightdim connect..
MODE 2 MOTION SENSOR
Motion sensor active. The luminaire switches itself on or off depending on whether it detects a
presence.
Motion sensor inactive. The luminaire has to be switched on or off via the switch.
MODE 3 CONSTANT LIGHT CONTROLLER
Constant light controller active. The luminaire dims istelf to the saved light level depending on the
ambient light level.
Constant light controller inactive. The luminaire has to be dimmed via the switch.
MODE 4 POWER ON
After an interruption to the power supply, the luminaire switches itself back on at 100%, inde-
pendent of whether the luminaire was switched on or off beforehand.
After an interruption to the power supply, the luminaire does not switch itself on, rather operates
in automatic mode.
MODE 5 SAVING THE LIGHT LEVEL
It is possible to save the light level by using the “Z“ button. The procedure takes about 10 se
conds, beginning with the blinking of the LED. After this 10 second pause, the light level will be
saved. The constant light controller dims the luminaire to this saved light level. We recommend
that after the light level has been saved, switching the Mode 5 “off“ in order to prevent accidental
re-saving.
“Save light level” function is blocked. Use of button “Z“ is not possible. The saved light level is pro-
tected against accidental re-saving.
MODE 6 SWARM FUNCTION
The optional swarm function LIGHTDIM CONNECT can be retrofitted and is available under the
article number PD51-0.
LIGHT LAG PERIOD
The light lag period can be selected between one minute and 30 minutes, as desired.
X minutes delay. If there is no motion over a time period of X minutes, the luminaire switches
itself off.
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
20