94
2.6.5. Replacing the blade fuse
When the internal blade fuse blew, replace it with new one following the procedures below.
Be sure to switch off the system power before accessing to the internal fuse for replacement. For the
method to switch off the power, refer to the Instruction Manual attached to the VX-2000DS/3000DS.
Step 1. Remove the VP amplifier's top panel.
Refer to
p. 89, "Removing the VP Power Amplifier’s top panel"
Step 2. Replace the Blade fuse.
Capacity
VP-2064: Blade-Type Fuse 7.5 A
VP-2122: Blade-Type Fuse 15 A
VP-2241: Blade-Type Fuse 25 A
VP-2421: Blade-Type Fuse 35 A
Note
After completing the replacement of the fuse, remove the cause of fuse blowout before turning on the system
power.
Blade fuse
Blade fuse
Blade fuse
CH1
CH2
CH1
CH2
CH3
CH4
[VP-2064 Blade fuse position]
[VP-2241/2421 Blade fuse position]
[VP-2122 Blade fuse position]
Rear panel
Rear panel
Rear panel
DRIVE PCB
DRIVE PCB
DRIVE PCB
WARNING