10
10. LAN connection terminal [LAN]
For PC communication using the SR-D8 PC
Software.
Connects to a 100BASE-TX-compatible network.
Connect this terminal to a PC via a switching hub.
Use RJ45 connector.
etherCON* connector can also be used. (See Tip
below.)
Note
Do not connect the LAN terminal directly to the
PC.
[LeD]
LINK indicator FULL indicator
• FULL indicator (orange)
Lit
Communicating with a switching hub
Unlit Undetected
• LINK indicator (green)
Lit
Linkage to a switching hub
Unlit Undetected
11. Ac inlet
Insert supplied power cord (2 m or 6.56 ft) into
this socket.
12. Analog input terminal [FAULT SIgNAL]
Removable terminal block (3P) with electronically-
balanced input.
(H: Hot, C: Cold, E: Ground)
This terminal is used for direct audio signal input
to the digital power amplifier, bypassing the
unit’s built-in CPU, when the Fault Contact input
terminal (5) is shorted.
Note
Up to 4 units’ terminals can be connected in
parallel.
13. Local link through terminal
[LOcAL LINk THrOUgH]
Outputs signals from SR-D8-M to SR-D8-S’s
Local link input terminal (14) when interconnecting
SR-D8-M and SR-D8-S units in 3-unit or 4-unit
configuration.
Use RJ45 connector.
etherCON* connector can also be used. (See Tip
below.)
[LeD]
ACTIVE indicator
No functions assigned
(always unlit)
• ACTIVE indicator (orange)
Lit
Connection to SR-D8-S possible.
Unlit Failure status
14. Local link input terminal [LOcAL LINk IN]
Accepts signals from SR-D8-M’s Local link output
terminal (8) or SR-D8-S’s Local link through
terminal (13) when interconnecting SR-D8-M and
SR-D8-S units in multi-unit configuration.
Use RJ45 connector.
etherCON* connector can also be used. (See Tip
below.)
[LeD]
LINK indicator
No functions assigned
(always unlit)
• LINK indicator (orange)
Lit
Connection to SR-D8-M complete.
Unlit Undetected
15. cord clamp
Fixes the power cord.
Tips
• Use STP Category 5 Standard straight through cable with RJ45 connectors.
• For etherCON* connectors, use Neutrik NE8MC or NEC8MC-B.
* etherCON is a trademark of Neutrik Co., Ltd.