FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS
Those functions of the CP-62 which require either the addition of specific units or processing in existing units are as mentioned below.
Before installation and adjustment of equipment, make sure to check your system.
(For Data Transmitting and Receiving units, refer to Part 2. "Function Selection for Data Transmitting and Receiving units" Page 46.)
Function
Talk-Back from
paging speaker
Conference
External PA Paging
Station Paging
(including Paging
Priority)
All call plus 15
individual paging
zones
Press-to-talk
Control
Emergency All-call
Paging
Indication and
Control
Additional Equipment
Required
Talk-Back Unit
Conference Unit
Paging Interface Unit
Paging Interface Unit
Paging Interface Unit
Paging Interface Unit
Paging Interface Unit
Data Transmitting Unit
Data Receiving Unit
Unit Model
Number
TK-12
CL-62
PI-62
PI-62
PI-62
(2 pcs)
PI-62
PI-62
DT-E11
DR-B61
Remarks
Not yet available for sale.
External PA Equipment is required.
1. Wiring of "Station Paging Assignment" located at
the back of the frame of the Exchange.
2. Cutting of LM-62 jumper wire to split station paging
system.
PI-62 Type 1
All-call +7 Paging
Zones (No. 0-7)
Connected
Not mounted
PI-62 Type 2
8 Zones (No. 8-15)
without All-call
Disconnected
Mounted
1. PI-62 Type 1 is different from PI-62 Type 2 in the
following parts being used in each unit.
Type
Parts
Jumper
Wire (JW)
R100
(220K
2. Solder the electrolytic capacitor (33 µF) to the
terminals, and "PO" and "No. 319" (paired with No.
312) for EX-620, "PO" and "No. 255" (paired with
No. 248) for EX-610 of "Station Paging Assignment"
on the rear of exchange frame. Do not connect No.
319 (255) to GND.
Polarity of capacitor . . . PO :
No. 319 (255):
For EX-620
For EX-610
1. Insert the PI-62 into the place allocated to the PI-62
Type 2.
2. You can use whichever type, type 1 or 2, of the
PI-62 but be sure not to connect the terminal
"No.319" (paired with the terminal No.312) of the
"Station Paging Assignment" to the ground (GND).
3. When you call any of the stations from No.232
(132) through 239 (139) and press the
key,
the corresponding relay contact in the PI unit will
close and open in step with the
key.
For example, calling the station No.232 (132) using
the
key causes the PI's relay zero (0) to
operate in step or calling the station No.234 causes
the PI's relay 2 to operate in step.
This feature may be used for Door Remote or tor
controlling Radio Transmitting/Receiving Equip-
ment through user provided interface.
This function works when the Handset substation
connected to No. 247 (147) is picked up or when the
privacy switch of a Hands-free Substation connected to
No. 247 (147) is moved from the ON to OFF position. If
your wish to use this specified line for any other
purpose, you need to make the device incorporating the
circuit similar to the one of the station but modified to
suit such purpose.
The number that can be mounted on the cabinet-mount
type exchange is one (1). Use the connection cable
YR-806.
When more than 2 pieces are mounted, we suggest you
use rack-mount type exchange. For connection between
the exchange and the DT-E11, use the YR-802, and
THE YR-803 for extension of the DT-E11.
Such devices as indicator, control unit, etc. can be made
by using this unit and 24 VDC power supply.
— 3 —