Installation Steps
3. Making the Electrical Connection
WARNING! ELECTRICAL
SHOCK HAZARD
Turn household power supply breaker off before
connecting wires. The oven must be connected
to a permanent and grounded supply. Failure to
follow these instructions can result in death, fire,
or electrical shock.
Figure 1
.
Option 1
: If Connecting to a 4-wire System:
Connect the white oven conduit wire to the
neutral (white) wire in the junction box
. See
Figure 1
.
5
.
Connect the bare grounding oven cable
wire to the green grounding wire in the
junction box
. See Figure 1.
6
Option 2
: If Local Codes DO NOT PERMIT
Connecting the Oven Ground Wire to Neutral
(White) Wire in Junction Box:
Connect the white oven cable wire to the
neutral (white) wire in junction box
. See
Figure 1
.
5
Connect the bare grounding oven cable
wire to the green grounding wire in the
junction box
. See Figure 1.
6
Option 3
: If Local Codes PERMIT Connecting
the Oven Ground Wire to Neutral (White) Wire
in the Junction Box:
Twist together and crimp the neutral (white)
oven cable wire to the oven bare ground
wire
. See Figure 2
.
5
Connect the crimped white/bare oven wire
to the neutral (white) power supply line in
the junction box
. See Figure 2.
6
This oven requires a separate, grounded
4-wire, 240 V (AC), 50 Amp service with its
own circuit breaker
.
Installation must
comply with National Electric Code.
L
See
“
Electrical Requirements
”.
It is strongly recommended to connect this oven
to 8 gauge copper wire.
Figure 2
.
STEPS
With oven positioned in front of cabinet opening,
disconnect the household power supply. Feed
house wiring through opening in the cabinet.
If using a junction box, thread oven cable into
junction box and secure with UL-listed conduit
connector.
L
See ”Cabinet Dimensions”
drawing
for recommended power location.
1
Connect the black wire from the household power
supply with black wire in the oven conduit using
twist-on connectors
.
2
Connect the red wire from the household power
supply with the red wire in the oven conduit using
twist-on connectors.
3
Follow local codes & ordinances to complete the
neutral and ground connection according to the
following options:
4
8