10 Side dispenser
error!
Side dispenser does not
rotate when the control
starts the dispensing
process
• The side dispenser has
stopped because of
jammed feed
• Fuse – F5 has tripped
• The belt is broken
• Side dispenser sensor
or cable are defective
• Side dispenser sensor
has shifted out of
position
• Remove jammed feed
• If the fuse has tripped, the
machine must wait 20 min
before
restarting. Press Reset
Alarms and the fuse is
automatically reset
• Check and adjust the tension
on the belt so that it bends in
both rotation directions
• Check the side dispenser
sensor and cable Check that
the sensor is counting
11 Maintenance
required
It is time to perform
maintenance on the
machine
• The 10-hour
maintenance interval
since the previous
maintenance engineer
reset the maintenance
counter in the Hour
meter menu has
elapsed.
• Maintenance must be
performed.
• Once maintenance is
complete, reset the
maintenance counter in the
menu
Hour meter
12 FK1 fault
Error in
the inverter for the
ceiling rail unit
• Incorrect voltage
• Overload in the ceiling
rail unit motors.
• Check power supply and
conductor rail
• Check ceiling rail unit motors
• Check that the rail track is
free of obstructions
13 FK2 fault
Error in
the inverter for the
conveyor belt
• Incorrect voltage
• Overload in conveyor
belt motor
• Check power supply and
conductor rail
• Check if the conveyor belt is
stuck.
• It should rotate freely
14 FK1
Communication
fault
• Communication error
between PLC and
the inverter for
the ceiling rail
unit – FK1
• Communication with
the inverter has been
lost
• Reset error message and try
again
• If the error recurs – contact
service personnel