background image

TKH 

 

TKH Security | Siqura WP10 | 

Installation manual v2.0

 

 

10 

Connecting the SA camera series 

Connecting a WP10 to a SA

-

PTZ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connecting a WP10 to a SA-FIX W 

 

 

 

 

WP10 Washer tank 

Mains 
power 

24Vac 

power 

WP10 Washer tank 

Mains 
power 

24Vac 

power 

Summary of Contents for Siqura WP10

Page 1: ...TKH TKH Security Siqura EX PD24 Installation manual 1 WP10 Installation manual Copyright 2021 TKH Security B V Version 2 0 ...

Page 2: ...e invite you to offer your suggestions and comments by email via info tkhsecurity com Your feedback will help us to further improve our documentation How to contact us If you have any comments or queries concerning any aspect related to the product do not hesitate to contact TKH Security B V Meridiaan 32 2801 DA Gouda Used electrical electronic and stainless steel products should not be mixed with...

Page 3: ...ents Contents 3 Description 4 Before you continue 5 Install the unit 6 Open the plastic box 6 Connecting the UPxx series 8 Connecting the HSG04 9 Connecting the SA camera series 10 Connecting a WP10 to a SA PTZ 10 Connecting a WP10 to a SA FIX W 10 Dimensions 11 ...

Page 4: ...marine camera series the UP traffic PTZ series and the HSG04 outdoor housing The WP10 is powered by 24 Vac and 100 Vac 240 Vac 50 60Hz supply voltage The units can be controlled using a 24 Vac control signal or a dry contact open collector signal The WP10 is fitted with a float switch that prevents the pump from running dry and indicates an empty tank by an contact closure output ...

Page 5: ...t must be tightly closed when operating Open only the covers pointed out in this installation manual The internal pump must not run dry to prevent failure A float switch with an empty tank alarm is available to prevent such damages The unit is intended to be used with water or with water ethanol solutions Other mixtures could obstruct the nozzle If the solution used has residual it must be filtere...

Page 6: ...nds Connect the power cable and control cable according the instructions below Close the plastic box tightly Connect the water hose to the nozzle M7 Pump control input Contact driven J1 Empty tank alarm setting Sets M3 to Normally Closed NC or Normally Open NO M4 Float switch pre connected M5 Pump control input 24Vac dc driven SA cams S1 Activates water pump test M1 Mains power connection 100 Vac ...

Page 7: ...7 Digital Enable Input activates the Water Pump when the input is closed DIS1 1 Power Supply Input Configuration 100 240Vac or 24Vdc SW1 OFF 0 24Vac by default SW1 ON 1 DIS1 2 Pump Motor Output Level Configuration SW2 shall always be OFF 0 J1 Level Alarm Output configuration NC or NO J2 Reserved J3 reserved J5 Pump motor Output Enabler turns the Water Pump always ON S1 Pump Motor Output Test Butto...

Page 8: ... control is connected by the ALARM out wires of the UPxx camera Cable Label Cable colour Remarks ALARM IN Black Not used GND Brown ALARM OUT NO Red Normally open Washer ALARM OUT NC Orange Normally closed ALARM OUT COM Yellow Common Washer UP33 UP36 WP10 Washer tank WP10 Mains power 24Vac power ...

Page 9: ...tion manual v2 0 9 Connecting the HSG04 The washer is controlled by alarm output DO2 from HSG04 The movement will be maintained by camera installed in HSG04 Detailed configuration please refer to HSG04 quick start guide WP10 To M7 Pin 1 2 ...

Page 10: ...y Siqura WP10 Installation manual v2 0 10 Connecting the SA camera series Connecting a WP10 to a SA PTZ Connecting a WP10 to a SA FIX W WP10 Washer tank Mains power 24Vac power WP10 Washer tank Mains power 24Vac power ...

Page 11: ...TKH TKH Security Siqura WP10 Installation manual v2 0 11 Dimensions Dimensions in mm ...

Page 12: ...TKH Security Proposal RFP Name RFP Number TKH Security Siqura EX PD24 Installation manual 12 Our Brands 2020 TKH Security tkhsecurity com 2021 TKH Security Our Brands ...

Reviews: