35
Maintenance Intervals
Intervall
Daily before use
Daily before use
Daily before use
Daily before use
Daily after use
Daily after use
Daily after use
Every 300 rivetings/ 25
operating hours
Every 5-10 000 rivetings
/ 500 operating hours
Activity
Check for cracks
Check the riveting tool for
wear
Check the air discharged
from the tool
Check for oil leaks from
the riveting tool
Oil the threads of the
mandrels/ internal-thread
mandrels
Clean riveting tool
Oil moving parts
(not Trigger (12))
Check the stroke setting
Change the hydraulic oil
How?
Visual check
Visual check/ Functional
check
Visual check, Remove dirt
Visual check,
if necessary refill the oil,
bleed the hydraulic system
Grease the thread with a
drop of non-corrosive oil
With a rag
With acid-free oil e.g.
ELFOLNA 46
Measuring stroke (H)
With acid-free oil e.g. DEA
Astron HLP 32
Who?
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Professional
Remark
Only specialists should chan-
ge the worn parts
Air may only be directly relea-
sed through the engine and
the valve in the floor plate
Readjust the nose piece after
every stroke adjustment
Oil changes should only be
carried out by specialists
Ms50_gb_241001_neu.qxd 30.10.2001 9:01 Uhr Seite 35
Summary of Contents for RIVETEC RL 50
Page 44: ......