Trouble shooting
Problems
Blind rivet is set correctly
Blind rivet can not be
inserted
Air adjustment nozzle is stuck
Cause
Supply of compressed air is too rare
Jaws are dirty
Jaws are worn out
Jaw case and jaw case body are
loose
Oil shortage/ no stroke
Oil quantity in the system too high
Wrong nose piece
Nose piece is loose
Travel-path of the mandrel is blocked
X-value is too low
The screw is too tight
Solution
(
O
) Check compressed air supply
(
O
) Set the compressed air setting on the mainten-
ance unit at a maximum of 7 bar
(
O
) Clean jaws
(
O
) Change jaws (see page 20 “Maintaining the
riveting tool”)
(
O
) Tighten the screws/ nuts (see page 20
“Maintaining the riveting tool”)
(
O
) Eliminate oil shortage
(
O
) Check and adapt oil quantity (see “Maintaining
the riveting tool”)
(
O
) Change nose piece (see page 17 “Operating
the riveting tool”)
(
O
) Tighten screws/ nuts (see page 20 “Maintaining
the riveting tool”)
(
O
) Empty riveting tool mandrel collector
(
O
) Reset the value of X (see page 24 “Adjusting
the jaw case body”)
(
P
) Change or clean O-ring