background image

HEAT GUN 2000W        TTB284HTG

ENVIRONMENTAL PROTECTION

              Waste electrical products should not be 

              disposed of with household waste. Please 

              recycle where facilities exist. Check with your 

Local Authority or retailer for recycling advice. For 

further information visit www.recyclemore.co.uk

UK PLUG REPLACEMENT

The fuse in the main plug of your power tool

should always be replaced with one of identical

rating.

Check the voltage given on your power tool

matches the supply voltage.

The power tool is supplied with a fitted plug,

however if you should need to fit a new plug

follows the instruction below.

IMPORTANT

The wire in the mains lead are coloured in

accordance with the following code:

Blue ---Neutral

Brown ---Live

The wire that is coloured 

blue

 must be connected

to the terminal that is marked with the letter 

N.

 The

wire that is coloured 

brown

 must be connected

to the terminal that is marked with the letter 

L.

A 13AMP (BS1363 or BS1363/A) plug must be

used and a 13 AMP fuse must be fitted.

13 AMP

FUSE

BROWN

L (LIVE)

CABLE GRIP

OUTER

SLEEVE

BLUE

N (NEUTRAL)

DECAPADOR TERMICO 2000W      TTB284HTG

MANTENIMIENTO

           

ADVERTENCIA: 

Asegúrese siempre de que la 

           decapador termico esté apagada, desconectada de 

la red eléctrica y se haya dejado enfriar antes de su 

limpieza o almacenaje.

Extraiga el enchufe de la toma de corriente antes 
de llevar a cabo cualquier ajuste, reparación o 
mantenimiento.

Su herramienta eléctrica no necesita mantenimiento o 

lubricación adicionales. Su herramienta no contiene partes 

reparables por el usuario. No use nunca agua o limpia-

dores químicos para limpiar su herramienta. Límpiela con 

un trapo seco. Guarde siempre su herramienta en un lugar 

seco. Mantenga las ranuras de ventilación del motor 

limpias. Mantenga todos los controles de funcionamiento 

libres de polvo. 

Puede que, ocasionalmente, observe chispas a través de 

las ranuras de ventilación. Esto es normal. Si el cable de 

alimentación está dañado, para evitar peligros, éste 

deberá ser sustituido por el fabricante, su agente 

autorizado o personas similarmente cualificadas.

DECAPEUR THERMIQUE  2000W      TTB284HTG

Déclaration de conformité

Nous, BRICO DEP

Ô

T – 30-32, rue de la Tourelle , 

91310 Longpont sur Orge - FRANCE

Déclarons, sous notre propre responsabilité, que l’appareil suivant :

Désignation:  DECAPEUR THERMIQUE 2000W

Référence : TTB284HTG

Code BRICO DEPÔT: 230352

Est conforme aux exigences essentielles listées ci-dessous:

Directive Basse Tension,

 2006/95/CE

EN 60335-1: 2002+A1: 2004+A11: 2004 +A12: 2006++A2: 2006+A13: 2008

EN 60335-2-45: 2002+ A1: 2008

EN62233:2008

Directive Compatibilité Electromagnétique, 

2004/108/CE

EN 55014-1: 2006+A1: 2009

EN 55014-2:1997+A1: 2001+A2: 2008

EN 61000-3-2: 2006

EN 61000-3-3: 2008

Fait à : Longpont sur orge

Le:   07/07/2010

Signataire et responsable de la documentation technique autorisé:

Jean Christophe Declerck– Directeur Commercial

BRICO DEP

Ô

T – 30-32, rue de la Tourelle , 91310 Longpont sur Orge - FRANCE

 

Summary of Contents for TTB284HTG

Page 1: ...W TTB284HTG 24 MANUAL DE INSTRUCCIONES Y SEGURIDAD Instrucciones originales DECAPADOR TERMICO 2000W TTB284HTG Garant a del fabricante meses 24 MANUEL D INSTRUCTIONS ET DE SECURITE Instructions origina...

Page 2: ...cubre los da os resultantes del desgaste normal falta de mantenimiento negligencia mala instalaci n o uso incorrecto golpes no cumplimiento de las recomendaciones de alimentaci n el ctricas almacenami...

Page 3: ...o dejarse en exteriores 7 Este aparato no est indicado para ser usado por personas incluyendo ni os con capacidades f sicas sensoriales o mentales reducidas o con falta de experiencia y conocimientos...

Page 4: ...YMBOLES Les produits lectriques ne doivent pas tre jet s directement avec les ordures m nag res Ce produit est marqu du symbole du tri s lectif relatif aux d chets d quipements lectriques et lectroniq...

Page 5: ...da de calor 2 Entrada de aire fr o 3 Interruptor de tres posiciones 4 Rasqueta 5 Cabezal concentrador 6 Cabezal plano 7 Cabezal de gancho 8 Cabezal de protecci n para cristales 1 5 4 6 7 8 2 3 DECAPEU...

Page 6: ...a de entrada Temperatura Flujo de aire 1 2 3 Clase de protecci n Peso de la m quina 230 240V 50Hz 2000W 50 C 350 l min 450 C 450 l min 600 C 550 l min II 0 8kg ACCESORIOS Rasqueta 1ud Cabezales 4uds C...

Page 7: ...Puede acoplar 4 cabezales de formas diferentes a la decapador termico que pueden usarse tal como se indica 1 Cabezal concentrador Fig 3 Este cabezal dirige un flujo de aire caliente concentrado hacia...

Page 8: ...la rasqueta destornille la tuerca de su extremo y acople la cuchilla en su lugar volviendo a colocar la tuerca y apret ndola La rasqueta triangular es ideal para eliminar pintura de bordes y superfici...

Page 9: ...tando en la direcci n correcta para desviar el aire caliente del cristal antes de encenderlo Gire el cabezal cuando cambie entre los travesa os horizontal y vertical Deje que el cabezal se enfr e ante...

Page 10: ...el pl stico se vuelva pegajoso luego aplique calor a la otra superficie Sostenga ambas junturas en el lugar deseado hasta que el pl stico se haya enfriado totalmente ADVERTENCIA El pl stico puede camb...

Page 11: ...ier ajuste reparaci n o mantenimiento Su herramienta el ctrica no necesita mantenimiento o lubricaci n adicionales Su herramienta no contiene partes reparables por el usuario No use nunca agua o limpi...

Page 12: ...ignatory and technical file holder Date 07 07 2010 Signature ________________ Name title Peter Harries Quality Manager Titan Power Tools UK Ltd Trade House Mead Avenue BA22 8RT Declaraci n de conformi...