  TROUBLESHOOTING

 

Main Lamp does not turn on when triggered 

 

Please check that your wiring connection is 
correct. 

 

Please make sure that the lamp is not blown. 

 
Main Lamp does not turn off at night 

 

Please confirm that your wiring connection is 
correct. 

 

Check that the LUX Control is turned fully 
clockwise to the moon position. 

 

Please check if movement in the detection area is 
constantly triggering the PIR. To test this cover 
the PIR detector completely with black insulating 
tape so no triggers can be seen by the PIR. If the 
main lamp then turns off this means that the PIR 
can see a constant trigger such as bushes, trees 
or other moving heat sources.

 

 
 

 

SPECIFICATIONS

 

Power Requirement 

AC 210 ~ 240V / 50Hz 

Lamp Rating 

Max. 13w Fluorescent or 
60w incandescent lamp 

Main Lamp Type 

E27 Screw Type Max. 
length 180mm 
Max. diameter 55mm 

LED Comfort Light 

0.6W Photocell Controlled 

PIR Sensor Angle 

Up to 110° at 2m Height 

Detection Range 

Up to 12m at 2m Height 

Mounting Height 

Recommended 1.8 ~ 2.5m 
Wall Mount   

Wall Switch Control 

Power On/Off 

Time Adjustment 

8 secs ~ 12 mins 

Lux Adjustment 

30 ~200 Lux 

Warm Up Time 

About 60 seconds 

Protection Class 

Class 1 – Must be earthed 

Protection Index 

IP44 

Specifications are subject to change without notice. 

TITANTLGPIRSS

                      2015/07                       

 
 

 

Environmental Concerns: 

Please  DO  NOT  dispose  of  electrical  appliances  as 
unsorted waste, use the recycling facilities provided by 
your local authorities. 
 
Please  DO  NOT  dispose  of  packaging  as  unsorted 
waste,  use  the  recycling  facilities  provided  by  your 
local authorities. 

Reviews: