TROUBLESHOOTING
Main Lamp does not turn on when triggered
Please check that your wiring connection is
correct.
Please make sure that the lamp is not blown.
Main Lamp does not turn off at night
Please confirm that your wiring connection is
correct.
Check that the LUX Control is turned fully
clockwise to the moon position.
Please check if movement in the detection area is
constantly triggering the PIR. To test this cover
the PIR detector completely with black insulating
tape so no triggers can be seen by the PIR. If the
main lamp then turns off this means that the PIR
can see a constant trigger such as bushes, trees
or other moving heat sources.
SPECIFICATIONS
Power Requirement
AC 210 ~ 240V / 50Hz
Lamp Rating
Max. 13w Fluorescent or
60w incandescent lamp
Main Lamp Type
E27 Screw Type Max.
length 180mm
Max. diameter 55mm
LED Comfort Light
0.6W Photocell Controlled
PIR Sensor Angle
Up to 110° at 2m Height
Detection Range
Up to 12m at 2m Height
Mounting Height
Recommended 1.8 ~ 2.5m
Wall Mount
Wall Switch Control
Power On/Off
Time Adjustment
8 secs ~ 12 mins
Lux Adjustment
30 ~200 Lux
Warm Up Time
About 60 seconds
Protection Class
Class 1 – Must be earthed
Protection Index
IP44
Specifications are subject to change without notice.
TITANTLGPIRSS
2015/07
Environmental Concerns:
Please DO NOT dispose of electrical appliances as
unsorted waste, use the recycling facilities provided by
your local authorities.
Please DO NOT dispose of packaging as unsorted
waste, use the recycling facilities provided by your
local authorities.