NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher
pressure and the PRImE/SPRAy valve is in the
SPRAy position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is operating
between 201 and 1900 PSI. A solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying stain,
lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates one of
the following:
a. Tip Wear Indicator — when spraying with latex or at high pressure
the solid yellow appears. This means the tip is worn and needs to
be replaced.
b. Tip Too Large — when a tip that is too large for the sprayer is put
in the gun, the pressure indicator will turn from solid green to solid
yellow.
c. Fluid Section Wear — if a solid yellow pressure indicator appears
when using a new tip and the pressure is set at maximum, service
may be required (worn packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating
between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oil-
based and latex house paints
• The sprayer is operating at peak performance at a high
pressure setting
motor Running Indicator
The Motor Running indicator is on when the motor is commanded to
run. This indicator is used by service centers to troubleshoot motor
problems.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure when
shutting the unit down for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
Trigger lock in
locked position.
1. Lock the gun by turning the gun trigger
lock to the locked position.
2. Turn off the sprayer by moving the ON/
OFF switch to the OFF position.
3. Turn the pressure control knob
counterclockwise to its OFF position in
the black zone.
4. Unlock the gun by turning the gun
trigger lock to the unlocked position.
5. Hold the metal part of the gun firmly to
the side of a metal container to ground
the gun and avoid a build up of static
electricity.
6. Trigger the gun to remove any pressure
that may still be in the hose.
7. Lock the gun by turning the gun trigger lock to
the locked position.
8. Move the PRIME/SPRAY valve down to the
PRIME position.
Xact Digital control System Operation (if equipped)
The Xact Digital Control System is an optional add-on that increases
the functionality of the sprayer. It is installed directly below the
pressure control knob on the control panel. It consists of a display
and four function keys. The display shows various menu screens that
allow the user to customize and monitor sprayer operation using the
function keys.
SET PSI
3000
ACTUAL PSI
2950
MENU
+
–
SELECT
4
3
2
1
Display
Function
Keys
NOTE: The pressure control knob overrides the Xact Digital
control System settings. Anytime the pressure
control knob is turned, the sprayer pressure will
change accordingly.
Function Keys
The function keys are numbered 1–4. Each key is labeled with an
additional function as well.
#1/menu Key
Pressing the #1 key scrolls through the available
menu screens or performs a function described
on the active menu screen.
#2/
p
Key
Pressing the #2 key performs a function
described on the active menu screen or increases
a value.
#3/
q
Key
Pressing the #3 key performs a function
described on the active menu screen or decrease
a value.
#4/Select Key
Pressing the #4 key selects the active menu
screen or performs a function described on the
active menu screen.
menu Screens
Several menu screens are available for the user to customize and
monitor sprayer operation. They include Main Screen, User Pre-
Sets, Volume Pumped, Job Volume, Unit Serial #, TImers, Job Timers,
Service Time, Pressure, Security Code, Prime, and Pulse Clean.
main Screen
SET PSI
3000
ACTUAL PSI
2950
The Main Screen is the default screen for
the control system at sprayer startup.
Pressing the #2 key switches between PSI and MPa units of measure.
Press the #1 key to scroll through the remaining menu screens.
User Pre-Sets Screen
USER PRE-SETS
SELECT-4
MENU-1
The User Pre-Sets screen allows the user
to set four different pressure settings and
save them for future use. To select the User Pre-Sets screen, press the
#4 key.
SELECT
PRE-SETS 1-4
Press keys 1 through 4 from the Select
screen to select or change a pre-set
pressure.
PSI SETTING
750
SELECT-4
CHG-2
Press the #4 key to select the setting and
the Main Screen will appear.
PRE-SET #1
750
PRESS +/- TO CHG
Press the #2 key to change the setting. On
the following screen, use the #2/+ key to
increase the setting or the #3/- screen to decrease the setting. Once
the desired setting has been reached, press the #4 key to set and the
Main Screen will appear. To select or change the remaining three
pre-sets, scroll to the User Pre-Sets screen and repeat the above
procedure.